  "federal_crosswalk": [
    {
      "record_id": "construction-01",
      "dataset_version": "1.0.0",
      "jurisdiction_level": "Federal",
      "jurisdiction_name": "United States",
      "workplace_category": "Ordinary construction",
      "standard_number": "29 CFR 1926.51",
      "requirement_type": "employee_count",
      "requirement_text": "20 or less: 1; 20 or more: 1 toilet seat and 1 urinal per 40 workers; 200 or more: 1 toilet seat and 1 urinal per 50 workers.",
      "employee_scope_text": "Employees at ordinary construction jobsites; Table D-1 is written using total employees/workers.",
      "minimum_facility_text": "20 or less: 1; 20 or more: 1 toilet seat and 1 urinal per 40 workers; 200 or more: 1 toilet seat and 1 urinal per 50 workers.",
      "portable_facility_status": "At jobsites without a sanitary sewer, qualifying privies, chemical toilets, recirculating toilets, or combustion toilets must be provided unless local codes prohibit them.",
      "access_rule": "The regulation states no distance or travel time. OSHA reads “provided” as prompt access and uses less than 10 minutes as the general starting point in its February 23, 2005 interpretation.",
      "service_rule": "No fixed interval in the regulation. An unsanitary toilet does not count as provided. OSHA’s May 17, 2006 interpretation cites ANSI-based weekly service for up to 10 users and twice-weekly service for 20 users as guidance, not a federal schedule.",
      "washing_rule": "Section 1926.51(f)(1) requires adequate nearby washing only for paints, coatings, herbicides, insecticides, or other harmful-contaminant operations. OSHA states that §1926.51(f)(3) applies only to permanent places of employment.",
      "privacy_lock_rule": "No inside-lock requirement is stated in §1926.51(c).",
      "sex_separation_rule": "No sex-separation requirement is stated in §1926.51(c).",
      "exception_text": "Paragraph (c) does not apply to mobile crews having transportation readily available to nearby toilet facilities.",
      "source_agency": "U.S. Occupational Safety and Health Administration",
      "source_title": "29 CFR 1926.51 — Sanitation",
      "source_url": "https://www.osha.gov/laws-regs/regulations/standardnumber/1926/1926.51",
      "source_document_date": "",
      "verification_date": "2026-07-27",
      "verification_tier": "★",
      "source_text_note": "Table D-1 overlaps at exactly 20 and exactly 200 employees; the middle row has no printed upper boundary."
    },
    {
      "record_id": "construction-02",
      "dataset_version": "1.0.0",
      "jurisdiction_level": "Federal",
      "jurisdiction_name": "United States",
      "workplace_category": "Ordinary construction",
      "standard_number": "29 CFR 1926.51",
      "requirement_type": "denominator",
      "requirement_text": "Employees at ordinary construction jobsites; Table D-1 is written using total employees/workers.",
      "employee_scope_text": "Employees at ordinary construction jobsites; Table D-1 is written using total employees/workers.",
      "minimum_facility_text": "20 or less: 1; 20 or more: 1 toilet seat and 1 urinal per 40 workers; 200 or more: 1 toilet seat and 1 urinal per 50 workers.",
      "portable_facility_status": "At jobsites without a sanitary sewer, qualifying privies, chemical toilets, recirculating toilets, or combustion toilets must be provided unless local codes prohibit them.",
      "access_rule": "The regulation states no distance or travel time. OSHA reads “provided” as prompt access and uses less than 10 minutes as the general starting point in its February 23, 2005 interpretation.",
      "service_rule": "No fixed interval in the regulation. An unsanitary toilet does not count as provided. OSHA’s May 17, 2006 interpretation cites ANSI-based weekly service for up to 10 users and twice-weekly service for 20 users as guidance, not a federal schedule.",
      "washing_rule": "Section 1926.51(f)(1) requires adequate nearby washing only for paints, coatings, herbicides, insecticides, or other harmful-contaminant operations. OSHA states that §1926.51(f)(3) applies only to permanent places of employment.",
      "privacy_lock_rule": "No inside-lock requirement is stated in §1926.51(c).",
      "sex_separation_rule": "No sex-separation requirement is stated in §1926.51(c).",
      "exception_text": "Paragraph (c) does not apply to mobile crews having transportation readily available to nearby toilet facilities.",
      "source_agency": "U.S. Occupational Safety and Health Administration",
      "source_title": "29 CFR 1926.51 — Sanitation",
      "source_url": "https://www.osha.gov/laws-regs/regulations/standardnumber/1926/1926.51",
      "source_document_date": "",
      "verification_date": "2026-07-27",
      "verification_tier": "★",
      "source_text_note": "Table D-1 overlaps at exactly 20 and exactly 200 employees; the middle row has no printed upper boundary."
    },
    {
      "record_id": "construction-03",
      "dataset_version": "1.0.0",
      "jurisdiction_level": "Federal",
      "jurisdiction_name": "United States",
      "workplace_category": "Ordinary construction",
      "standard_number": "29 CFR 1926.51",
      "requirement_type": "portable_units",
      "requirement_text": "At jobsites without a sanitary sewer, qualifying privies, chemical toilets, recirculating toilets, or combustion toilets must be provided unless local codes prohibit them.",
      "employee_scope_text": "Employees at ordinary construction jobsites; Table D-1 is written using total employees/workers.",
      "minimum_facility_text": "20 or less: 1; 20 or more: 1 toilet seat and 1 urinal per 40 workers; 200 or more: 1 toilet seat and 1 urinal per 50 workers.",
      "portable_facility_status": "At jobsites without a sanitary sewer, qualifying privies, chemical toilets, recirculating toilets, or combustion toilets must be provided unless local codes prohibit them.",
      "access_rule": "The regulation states no distance or travel time. OSHA reads “provided” as prompt access and uses less than 10 minutes as the general starting point in its February 23, 2005 interpretation.",
      "service_rule": "No fixed interval in the regulation. An unsanitary toilet does not count as provided. OSHA’s May 17, 2006 interpretation cites ANSI-based weekly service for up to 10 users and twice-weekly service for 20 users as guidance, not a federal schedule.",
      "washing_rule": "Section 1926.51(f)(1) requires adequate nearby washing only for paints, coatings, herbicides, insecticides, or other harmful-contaminant operations. OSHA states that §1926.51(f)(3) applies only to permanent places of employment.",
      "privacy_lock_rule": "No inside-lock requirement is stated in §1926.51(c).",
      "sex_separation_rule": "No sex-separation requirement is stated in §1926.51(c).",
      "exception_text": "Paragraph (c) does not apply to mobile crews having transportation readily available to nearby toilet facilities.",
      "source_agency": "U.S. Occupational Safety and Health Administration",
      "source_title": "29 CFR 1926.51 — Sanitation",
      "source_url": "https://www.osha.gov/laws-regs/regulations/standardnumber/1926/1926.51",
      "source_document_date": "",
      "verification_date": "2026-07-27",
      "verification_tier": "★",
      "source_text_note": "Table D-1 overlaps at exactly 20 and exactly 200 employees; the middle row has no printed upper boundary."
    },
    {
      "record_id": "construction-04",
      "dataset_version": "1.0.0",
      "jurisdiction_level": "Federal",
      "jurisdiction_name": "United States",
      "workplace_category": "Ordinary construction",
      "standard_number": "29 CFR 1926.51",
      "requirement_type": "access",
      "requirement_text": "The regulation states no distance or travel time. OSHA reads “provided” as prompt access and uses less than 10 minutes as the general starting point in its February 23, 2005 interpretation.",
      "employee_scope_text": "Employees at ordinary construction jobsites; Table D-1 is written using total employees/workers.",
      "minimum_facility_text": "20 or less: 1; 20 or more: 1 toilet seat and 1 urinal per 40 workers; 200 or more: 1 toilet seat and 1 urinal per 50 workers.",
      "portable_facility_status": "At jobsites without a sanitary sewer, qualifying privies, chemical toilets, recirculating toilets, or combustion toilets must be provided unless local codes prohibit them.",
      "access_rule": "The regulation states no distance or travel time. OSHA reads “provided” as prompt access and uses less than 10 minutes as the general starting point in its February 23, 2005 interpretation.",
      "service_rule": "No fixed interval in the regulation. An unsanitary toilet does not count as provided. OSHA’s May 17, 2006 interpretation cites ANSI-based weekly service for up to 10 users and twice-weekly service for 20 users as guidance, not a federal schedule.",
      "washing_rule": "Section 1926.51(f)(1) requires adequate nearby washing only for paints, coatings, herbicides, insecticides, or other harmful-contaminant operations. OSHA states that §1926.51(f)(3) applies only to permanent places of employment.",
      "privacy_lock_rule": "No inside-lock requirement is stated in §1926.51(c).",
      "sex_separation_rule": "No sex-separation requirement is stated in §1926.51(c).",
      "exception_text": "Paragraph (c) does not apply to mobile crews having transportation readily available to nearby toilet facilities.",
      "source_agency": "U.S. Occupational Safety and Health Administration",
      "source_title": "29 CFR 1926.51 — Sanitation",
      "source_url": "https://www.osha.gov/laws-regs/regulations/standardnumber/1926/1926.51",
      "source_document_date": "",
      "verification_date": "2026-07-27",
      "verification_tier": "★",
      "source_text_note": "Table D-1 overlaps at exactly 20 and exactly 200 employees; the middle row has no printed upper boundary."
    },
    {
      "record_id": "construction-05",
      "dataset_version": "1.0.0",
      "jurisdiction_level": "Federal",
      "jurisdiction_name": "United States",
      "workplace_category": "Ordinary construction",
      "standard_number": "29 CFR 1926.51",
      "requirement_type": "servicing",
      "requirement_text": "No fixed interval in the regulation. An unsanitary toilet does not count as provided. OSHA’s May 17, 2006 interpretation cites ANSI-based weekly service for up to 10 users and twice-weekly service for 20 users as guidance, not a federal schedule.",
      "employee_scope_text": "Employees at ordinary construction jobsites; Table D-1 is written using total employees/workers.",
      "minimum_facility_text": "20 or less: 1; 20 or more: 1 toilet seat and 1 urinal per 40 workers; 200 or more: 1 toilet seat and 1 urinal per 50 workers.",
      "portable_facility_status": "At jobsites without a sanitary sewer, qualifying privies, chemical toilets, recirculating toilets, or combustion toilets must be provided unless local codes prohibit them.",
      "access_rule": "The regulation states no distance or travel time. OSHA reads “provided” as prompt access and uses less than 10 minutes as the general starting point in its February 23, 2005 interpretation.",
      "service_rule": "No fixed interval in the regulation. An unsanitary toilet does not count as provided. OSHA’s May 17, 2006 interpretation cites ANSI-based weekly service for up to 10 users and twice-weekly service for 20 users as guidance, not a federal schedule.",
      "washing_rule": "Section 1926.51(f)(1) requires adequate nearby washing only for paints, coatings, herbicides, insecticides, or other harmful-contaminant operations. OSHA states that §1926.51(f)(3) applies only to permanent places of employment.",
      "privacy_lock_rule": "No inside-lock requirement is stated in §1926.51(c).",
      "sex_separation_rule": "No sex-separation requirement is stated in §1926.51(c).",
      "exception_text": "Paragraph (c) does not apply to mobile crews having transportation readily available to nearby toilet facilities.",
      "source_agency": "U.S. Occupational Safety and Health Administration",
      "source_title": "29 CFR 1926.51 — Sanitation",
      "source_url": "https://www.osha.gov/laws-regs/regulations/standardnumber/1926/1926.51",
      "source_document_date": "",
      "verification_date": "2026-07-27",
      "verification_tier": "★",
      "source_text_note": "Table D-1 overlaps at exactly 20 and exactly 200 employees; the middle row has no printed upper boundary."
    },
    {
      "record_id": "construction-06",
      "dataset_version": "1.0.0",
      "jurisdiction_level": "Federal",
      "jurisdiction_name": "United States",
      "workplace_category": "Ordinary construction",
      "standard_number": "29 CFR 1926.51",
      "requirement_type": "washing",
      "requirement_text": "Section 1926.51(f)(1) requires adequate nearby washing only for paints, coatings, herbicides, insecticides, or other harmful-contaminant operations. OSHA states that §1926.51(f)(3) applies only to permanent places of employment.",
      "employee_scope_text": "Employees at ordinary construction jobsites; Table D-1 is written using total employees/workers.",
      "minimum_facility_text": "20 or less: 1; 20 or more: 1 toilet seat and 1 urinal per 40 workers; 200 or more: 1 toilet seat and 1 urinal per 50 workers.",
      "portable_facility_status": "At jobsites without a sanitary sewer, qualifying privies, chemical toilets, recirculating toilets, or combustion toilets must be provided unless local codes prohibit them.",
      "access_rule": "The regulation states no distance or travel time. OSHA reads “provided” as prompt access and uses less than 10 minutes as the general starting point in its February 23, 2005 interpretation.",
      "service_rule": "No fixed interval in the regulation. An unsanitary toilet does not count as provided. OSHA’s May 17, 2006 interpretation cites ANSI-based weekly service for up to 10 users and twice-weekly service for 20 users as guidance, not a federal schedule.",
      "washing_rule": "Section 1926.51(f)(1) requires adequate nearby washing only for paints, coatings, herbicides, insecticides, or other harmful-contaminant operations. OSHA states that §1926.51(f)(3) applies only to permanent places of employment.",
      "privacy_lock_rule": "No inside-lock requirement is stated in §1926.51(c).",
      "sex_separation_rule": "No sex-separation requirement is stated in §1926.51(c).",
      "exception_text": "Paragraph (c) does not apply to mobile crews having transportation readily available to nearby toilet facilities.",
      "source_agency": "U.S. Occupational Safety and Health Administration",
      "source_title": "29 CFR 1926.51 — Sanitation",
      "source_url": "https://www.osha.gov/laws-regs/regulations/standardnumber/1926/1926.51",
      "source_document_date": "",
      "verification_date": "2026-07-27",
      "verification_tier": "★",
      "source_text_note": "Table D-1 overlaps at exactly 20 and exactly 200 employees; the middle row has no printed upper boundary."
    },
    {
      "record_id": "construction-07",
      "dataset_version": "1.0.0",
      "jurisdiction_level": "Federal",
      "jurisdiction_name": "United States",
      "workplace_category": "Ordinary construction",
      "standard_number": "29 CFR 1926.51",
      "requirement_type": "privacy_lock",
      "requirement_text": "No inside-lock requirement is stated in §1926.51(c).",
      "employee_scope_text": "Employees at ordinary construction jobsites; Table D-1 is written using total employees/workers.",
      "minimum_facility_text": "20 or less: 1; 20 or more: 1 toilet seat and 1 urinal per 40 workers; 200 or more: 1 toilet seat and 1 urinal per 50 workers.",
      "portable_facility_status": "At jobsites without a sanitary sewer, qualifying privies, chemical toilets, recirculating toilets, or combustion toilets must be provided unless local codes prohibit them.",
      "access_rule": "The regulation states no distance or travel time. OSHA reads “provided” as prompt access and uses less than 10 minutes as the general starting point in its February 23, 2005 interpretation.",
      "service_rule": "No fixed interval in the regulation. An unsanitary toilet does not count as provided. OSHA’s May 17, 2006 interpretation cites ANSI-based weekly service for up to 10 users and twice-weekly service for 20 users as guidance, not a federal schedule.",
      "washing_rule": "Section 1926.51(f)(1) requires adequate nearby washing only for paints, coatings, herbicides, insecticides, or other harmful-contaminant operations. OSHA states that §1926.51(f)(3) applies only to permanent places of employment.",
      "privacy_lock_rule": "No inside-lock requirement is stated in §1926.51(c).",
      "sex_separation_rule": "No sex-separation requirement is stated in §1926.51(c).",
      "exception_text": "Paragraph (c) does not apply to mobile crews having transportation readily available to nearby toilet facilities.",
      "source_agency": "U.S. Occupational Safety and Health Administration",
      "source_title": "29 CFR 1926.51 — Sanitation",
      "source_url": "https://www.osha.gov/laws-regs/regulations/standardnumber/1926/1926.51",
      "source_document_date": "",
      "verification_date": "2026-07-27",
      "verification_tier": "★",
      "source_text_note": "Table D-1 overlaps at exactly 20 and exactly 200 employees; the middle row has no printed upper boundary."
    },
    {
      "record_id": "construction-08",
      "dataset_version": "1.0.0",
      "jurisdiction_level": "Federal",
      "jurisdiction_name": "United States",
      "workplace_category": "Ordinary construction",
      "standard_number": "29 CFR 1926.51",
      "requirement_type": "sex_separation",
      "requirement_text": "No sex-separation requirement is stated in §1926.51(c).",
      "employee_scope_text": "Employees at ordinary construction jobsites; Table D-1 is written using total employees/workers.",
      "minimum_facility_text": "20 or less: 1; 20 or more: 1 toilet seat and 1 urinal per 40 workers; 200 or more: 1 toilet seat and 1 urinal per 50 workers.",
      "portable_facility_status": "At jobsites without a sanitary sewer, qualifying privies, chemical toilets, recirculating toilets, or combustion toilets must be provided unless local codes prohibit them.",
      "access_rule": "The regulation states no distance or travel time. OSHA reads “provided” as prompt access and uses less than 10 minutes as the general starting point in its February 23, 2005 interpretation.",
      "service_rule": "No fixed interval in the regulation. An unsanitary toilet does not count as provided. OSHA’s May 17, 2006 interpretation cites ANSI-based weekly service for up to 10 users and twice-weekly service for 20 users as guidance, not a federal schedule.",
      "washing_rule": "Section 1926.51(f)(1) requires adequate nearby washing only for paints, coatings, herbicides, insecticides, or other harmful-contaminant operations. OSHA states that §1926.51(f)(3) applies only to permanent places of employment.",
      "privacy_lock_rule": "No inside-lock requirement is stated in §1926.51(c).",
      "sex_separation_rule": "No sex-separation requirement is stated in §1926.51(c).",
      "exception_text": "Paragraph (c) does not apply to mobile crews having transportation readily available to nearby toilet facilities.",
      "source_agency": "U.S. Occupational Safety and Health Administration",
      "source_title": "29 CFR 1926.51 — Sanitation",
      "source_url": "https://www.osha.gov/laws-regs/regulations/standardnumber/1926/1926.51",
      "source_document_date": "",
      "verification_date": "2026-07-27",
      "verification_tier": "★",
      "source_text_note": "Table D-1 overlaps at exactly 20 and exactly 200 employees; the middle row has no printed upper boundary."
    },
    {
      "record_id": "construction-09",
      "dataset_version": "1.0.0",
      "jurisdiction_level": "Federal",
      "jurisdiction_name": "United States",
      "workplace_category": "Ordinary construction",
      "standard_number": "29 CFR 1926.51",
      "requirement_type": "exceptions",
      "requirement_text": "Paragraph (c) does not apply to mobile crews having transportation readily available to nearby toilet facilities.",
      "employee_scope_text": "Employees at ordinary construction jobsites; Table D-1 is written using total employees/workers.",
      "minimum_facility_text": "20 or less: 1; 20 or more: 1 toilet seat and 1 urinal per 40 workers; 200 or more: 1 toilet seat and 1 urinal per 50 workers.",
      "portable_facility_status": "At jobsites without a sanitary sewer, qualifying privies, chemical toilets, recirculating toilets, or combustion toilets must be provided unless local codes prohibit them.",
      "access_rule": "The regulation states no distance or travel time. OSHA reads “provided” as prompt access and uses less than 10 minutes as the general starting point in its February 23, 2005 interpretation.",
      "service_rule": "No fixed interval in the regulation. An unsanitary toilet does not count as provided. OSHA’s May 17, 2006 interpretation cites ANSI-based weekly service for up to 10 users and twice-weekly service for 20 users as guidance, not a federal schedule.",
      "washing_rule": "Section 1926.51(f)(1) requires adequate nearby washing only for paints, coatings, herbicides, insecticides, or other harmful-contaminant operations. OSHA states that §1926.51(f)(3) applies only to permanent places of employment.",
      "privacy_lock_rule": "No inside-lock requirement is stated in §1926.51(c).",
      "sex_separation_rule": "No sex-separation requirement is stated in §1926.51(c).",
      "exception_text": "Paragraph (c) does not apply to mobile crews having transportation readily available to nearby toilet facilities.",
      "source_agency": "U.S. Occupational Safety and Health Administration",
      "source_title": "29 CFR 1926.51 — Sanitation",
      "source_url": "https://www.osha.gov/laws-regs/regulations/standardnumber/1926/1926.51",
      "source_document_date": "",
      "verification_date": "2026-07-27",
      "verification_tier": "★",
      "source_text_note": "Table D-1 overlaps at exactly 20 and exactly 200 employees; the middle row has no printed upper boundary."
    },
    {
      "record_id": "general-industry-01",
      "dataset_version": "1.0.0",
      "jurisdiction_level": "Federal",
      "jurisdiction_name": "United States",
      "workplace_category": "General industry / permanent workplaces",
      "standard_number": "29 CFR 1910.141",
      "requirement_type": "employee_count",
      "requirement_text": "Per sex: 1–15: 1 water closet; 16–35: 2; 36–55: 3; 56–80: 4; 81–110: 5; 111–150: 6; over 150: 1 additional fixture per additional 40 employees.",
      "employee_scope_text": "Permanent places of employment. “Number of employees” means the maximum number present at any one time on a regular shift; Table J-1 is calculated per sex.",
      "minimum_facility_text": "Per sex: 1–15: 1 water closet; 16–35: 2; 36–55: 3; 56–80: 4; 81–110: 5; 111–150: 6; over 150: 1 additional fixture per additional 40 employees.",
      "portable_facility_status": "Portable substitution may be treated as a de minimis departure only under the conditions described in OSHA’s May 18, 1999 interpretation, including impracticability of water carriage or temporary installation and adequate access, lighting, security, temperature control when needed, maintenance, and servicing.",
      "access_rule": "Mobile crews and normally unattended locations are excepted only when transportation is immediately available to nearby compliant toilet facilities. OSHA requires prompt access and reasonable restrictions.",
      "service_rule": "Toilet rooms and facilities must be sanitary. Under the 1999 portable-substitution interpretation, units must be well maintained and serviced.",
      "washing_rule": "Lavatories must have hot and cold or tepid running water, cleansing agents, and individual drying facilities, subject to the mobile-crew and unattended-location exception.",
      "privacy_lock_rule": "Each water closet must occupy a separate compartment that assures privacy. A single-occupancy room may serve all sexes only if it can be locked from the inside and contains at least one water closet.",
      "sex_separation_rule": "Separate toilet rooms must be provided for each sex, subject to the lockable single-occupancy exception. Where facilities will not be used by women, urinals may be substituted for water closets, but the number of water closets may not be reduced below two-thirds of the minimum.",
      "exception_text": "Mobile crews and normally unattended locations are excepted when transportation is immediately available to nearby facilities meeting the standard.",
      "source_agency": "U.S. Occupational Safety and Health Administration",
      "source_title": "29 CFR 1910.141 — Sanitation",
      "source_url": "https://www.osha.gov/laws-regs/regulations/standardnumber/1910/1910.141",
      "source_document_date": "",
      "verification_date": "2026-07-27",
      "verification_tier": "★",
      "source_text_note": "Table J-1 bands do not overlap; counts are per sex and based on the maximum number present at one time on a regular shift."
    },
    {
      "record_id": "general-industry-02",
      "dataset_version": "1.0.0",
      "jurisdiction_level": "Federal",
      "jurisdiction_name": "United States",
      "workplace_category": "General industry / permanent workplaces",
      "standard_number": "29 CFR 1910.141",
      "requirement_type": "denominator",
      "requirement_text": "Permanent places of employment. “Number of employees” means the maximum number present at any one time on a regular shift; Table J-1 is calculated per sex.",
      "employee_scope_text": "Permanent places of employment. “Number of employees” means the maximum number present at any one time on a regular shift; Table J-1 is calculated per sex.",
      "minimum_facility_text": "Per sex: 1–15: 1 water closet; 16–35: 2; 36–55: 3; 56–80: 4; 81–110: 5; 111–150: 6; over 150: 1 additional fixture per additional 40 employees.",
      "portable_facility_status": "Portable substitution may be treated as a de minimis departure only under the conditions described in OSHA’s May 18, 1999 interpretation, including impracticability of water carriage or temporary installation and adequate access, lighting, security, temperature control when needed, maintenance, and servicing.",
      "access_rule": "Mobile crews and normally unattended locations are excepted only when transportation is immediately available to nearby compliant toilet facilities. OSHA requires prompt access and reasonable restrictions.",
      "service_rule": "Toilet rooms and facilities must be sanitary. Under the 1999 portable-substitution interpretation, units must be well maintained and serviced.",
      "washing_rule": "Lavatories must have hot and cold or tepid running water, cleansing agents, and individual drying facilities, subject to the mobile-crew and unattended-location exception.",
      "privacy_lock_rule": "Each water closet must occupy a separate compartment that assures privacy. A single-occupancy room may serve all sexes only if it can be locked from the inside and contains at least one water closet.",
      "sex_separation_rule": "Separate toilet rooms must be provided for each sex, subject to the lockable single-occupancy exception. Where facilities will not be used by women, urinals may be substituted for water closets, but the number of water closets may not be reduced below two-thirds of the minimum.",
      "exception_text": "Mobile crews and normally unattended locations are excepted when transportation is immediately available to nearby facilities meeting the standard.",
      "source_agency": "U.S. Occupational Safety and Health Administration",
      "source_title": "29 CFR 1910.141 — Sanitation",
      "source_url": "https://www.osha.gov/laws-regs/regulations/standardnumber/1910/1910.141",
      "source_document_date": "",
      "verification_date": "2026-07-27",
      "verification_tier": "★",
      "source_text_note": "Table J-1 bands do not overlap; counts are per sex and based on the maximum number present at one time on a regular shift."
    },
    {
      "record_id": "general-industry-03",
      "dataset_version": "1.0.0",
      "jurisdiction_level": "Federal",
      "jurisdiction_name": "United States",
      "workplace_category": "General industry / permanent workplaces",
      "standard_number": "29 CFR 1910.141",
      "requirement_type": "portable_units",
      "requirement_text": "Portable substitution may be treated as a de minimis departure only under the conditions described in OSHA’s May 18, 1999 interpretation, including impracticability of water carriage or temporary installation and adequate access, lighting, security, temperature control when needed, maintenance, and servicing.",
      "employee_scope_text": "Permanent places of employment. “Number of employees” means the maximum number present at any one time on a regular shift; Table J-1 is calculated per sex.",
      "minimum_facility_text": "Per sex: 1–15: 1 water closet; 16–35: 2; 36–55: 3; 56–80: 4; 81–110: 5; 111–150: 6; over 150: 1 additional fixture per additional 40 employees.",
      "portable_facility_status": "Portable substitution may be treated as a de minimis departure only under the conditions described in OSHA’s May 18, 1999 interpretation, including impracticability of water carriage or temporary installation and adequate access, lighting, security, temperature control when needed, maintenance, and servicing.",
      "access_rule": "Mobile crews and normally unattended locations are excepted only when transportation is immediately available to nearby compliant toilet facilities. OSHA requires prompt access and reasonable restrictions.",
      "service_rule": "Toilet rooms and facilities must be sanitary. Under the 1999 portable-substitution interpretation, units must be well maintained and serviced.",
      "washing_rule": "Lavatories must have hot and cold or tepid running water, cleansing agents, and individual drying facilities, subject to the mobile-crew and unattended-location exception.",
      "privacy_lock_rule": "Each water closet must occupy a separate compartment that assures privacy. A single-occupancy room may serve all sexes only if it can be locked from the inside and contains at least one water closet.",
      "sex_separation_rule": "Separate toilet rooms must be provided for each sex, subject to the lockable single-occupancy exception. Where facilities will not be used by women, urinals may be substituted for water closets, but the number of water closets may not be reduced below two-thirds of the minimum.",
      "exception_text": "Mobile crews and normally unattended locations are excepted when transportation is immediately available to nearby facilities meeting the standard.",
      "source_agency": "U.S. Occupational Safety and Health Administration",
      "source_title": "29 CFR 1910.141 — Sanitation",
      "source_url": "https://www.osha.gov/laws-regs/regulations/standardnumber/1910/1910.141",
      "source_document_date": "",
      "verification_date": "2026-07-27",
      "verification_tier": "★",
      "source_text_note": "Table J-1 bands do not overlap; counts are per sex and based on the maximum number present at one time on a regular shift."
    },
    {
      "record_id": "general-industry-04",
      "dataset_version": "1.0.0",
      "jurisdiction_level": "Federal",
      "jurisdiction_name": "United States",
      "workplace_category": "General industry / permanent workplaces",
      "standard_number": "29 CFR 1910.141",
      "requirement_type": "access",
      "requirement_text": "Mobile crews and normally unattended locations are excepted only when transportation is immediately available to nearby compliant toilet facilities. OSHA requires prompt access and reasonable restrictions.",
      "employee_scope_text": "Permanent places of employment. “Number of employees” means the maximum number present at any one time on a regular shift; Table J-1 is calculated per sex.",
      "minimum_facility_text": "Per sex: 1–15: 1 water closet; 16–35: 2; 36–55: 3; 56–80: 4; 81–110: 5; 111–150: 6; over 150: 1 additional fixture per additional 40 employees.",
      "portable_facility_status": "Portable substitution may be treated as a de minimis departure only under the conditions described in OSHA’s May 18, 1999 interpretation, including impracticability of water carriage or temporary installation and adequate access, lighting, security, temperature control when needed, maintenance, and servicing.",
      "access_rule": "Mobile crews and normally unattended locations are excepted only when transportation is immediately available to nearby compliant toilet facilities. OSHA requires prompt access and reasonable restrictions.",
      "service_rule": "Toilet rooms and facilities must be sanitary. Under the 1999 portable-substitution interpretation, units must be well maintained and serviced.",
      "washing_rule": "Lavatories must have hot and cold or tepid running water, cleansing agents, and individual drying facilities, subject to the mobile-crew and unattended-location exception.",
      "privacy_lock_rule": "Each water closet must occupy a separate compartment that assures privacy. A single-occupancy room may serve all sexes only if it can be locked from the inside and contains at least one water closet.",
      "sex_separation_rule": "Separate toilet rooms must be provided for each sex, subject to the lockable single-occupancy exception. Where facilities will not be used by women, urinals may be substituted for water closets, but the number of water closets may not be reduced below two-thirds of the minimum.",
      "exception_text": "Mobile crews and normally unattended locations are excepted when transportation is immediately available to nearby facilities meeting the standard.",
      "source_agency": "U.S. Occupational Safety and Health Administration",
      "source_title": "29 CFR 1910.141 — Sanitation",
      "source_url": "https://www.osha.gov/laws-regs/regulations/standardnumber/1910/1910.141",
      "source_document_date": "",
      "verification_date": "2026-07-27",
      "verification_tier": "★",
      "source_text_note": "Table J-1 bands do not overlap; counts are per sex and based on the maximum number present at one time on a regular shift."
    },
    {
      "record_id": "general-industry-05",
      "dataset_version": "1.0.0",
      "jurisdiction_level": "Federal",
      "jurisdiction_name": "United States",
      "workplace_category": "General industry / permanent workplaces",
      "standard_number": "29 CFR 1910.141",
      "requirement_type": "servicing",
      "requirement_text": "Toilet rooms and facilities must be sanitary. Under the 1999 portable-substitution interpretation, units must be well maintained and serviced.",
      "employee_scope_text": "Permanent places of employment. “Number of employees” means the maximum number present at any one time on a regular shift; Table J-1 is calculated per sex.",
      "minimum_facility_text": "Per sex: 1–15: 1 water closet; 16–35: 2; 36–55: 3; 56–80: 4; 81–110: 5; 111–150: 6; over 150: 1 additional fixture per additional 40 employees.",
      "portable_facility_status": "Portable substitution may be treated as a de minimis departure only under the conditions described in OSHA’s May 18, 1999 interpretation, including impracticability of water carriage or temporary installation and adequate access, lighting, security, temperature control when needed, maintenance, and servicing.",
      "access_rule": "Mobile crews and normally unattended locations are excepted only when transportation is immediately available to nearby compliant toilet facilities. OSHA requires prompt access and reasonable restrictions.",
      "service_rule": "Toilet rooms and facilities must be sanitary. Under the 1999 portable-substitution interpretation, units must be well maintained and serviced.",
      "washing_rule": "Lavatories must have hot and cold or tepid running water, cleansing agents, and individual drying facilities, subject to the mobile-crew and unattended-location exception.",
      "privacy_lock_rule": "Each water closet must occupy a separate compartment that assures privacy. A single-occupancy room may serve all sexes only if it can be locked from the inside and contains at least one water closet.",
      "sex_separation_rule": "Separate toilet rooms must be provided for each sex, subject to the lockable single-occupancy exception. Where facilities will not be used by women, urinals may be substituted for water closets, but the number of water closets may not be reduced below two-thirds of the minimum.",
      "exception_text": "Mobile crews and normally unattended locations are excepted when transportation is immediately available to nearby facilities meeting the standard.",
      "source_agency": "U.S. Occupational Safety and Health Administration",
      "source_title": "29 CFR 1910.141 — Sanitation",
      "source_url": "https://www.osha.gov/laws-regs/regulations/standardnumber/1910/1910.141",
      "source_document_date": "",
      "verification_date": "2026-07-27",
      "verification_tier": "★",
      "source_text_note": "Table J-1 bands do not overlap; counts are per sex and based on the maximum number present at one time on a regular shift."
    },
    {
      "record_id": "general-industry-06",
      "dataset_version": "1.0.0",
      "jurisdiction_level": "Federal",
      "jurisdiction_name": "United States",
      "workplace_category": "General industry / permanent workplaces",
      "standard_number": "29 CFR 1910.141",
      "requirement_type": "washing",
      "requirement_text": "Lavatories must have hot and cold or tepid running water, cleansing agents, and individual drying facilities, subject to the mobile-crew and unattended-location exception.",
      "employee_scope_text": "Permanent places of employment. “Number of employees” means the maximum number present at any one time on a regular shift; Table J-1 is calculated per sex.",
      "minimum_facility_text": "Per sex: 1–15: 1 water closet; 16–35: 2; 36–55: 3; 56–80: 4; 81–110: 5; 111–150: 6; over 150: 1 additional fixture per additional 40 employees.",
      "portable_facility_status": "Portable substitution may be treated as a de minimis departure only under the conditions described in OSHA’s May 18, 1999 interpretation, including impracticability of water carriage or temporary installation and adequate access, lighting, security, temperature control when needed, maintenance, and servicing.",
      "access_rule": "Mobile crews and normally unattended locations are excepted only when transportation is immediately available to nearby compliant toilet facilities. OSHA requires prompt access and reasonable restrictions.",
      "service_rule": "Toilet rooms and facilities must be sanitary. Under the 1999 portable-substitution interpretation, units must be well maintained and serviced.",
      "washing_rule": "Lavatories must have hot and cold or tepid running water, cleansing agents, and individual drying facilities, subject to the mobile-crew and unattended-location exception.",
      "privacy_lock_rule": "Each water closet must occupy a separate compartment that assures privacy. A single-occupancy room may serve all sexes only if it can be locked from the inside and contains at least one water closet.",
      "sex_separation_rule": "Separate toilet rooms must be provided for each sex, subject to the lockable single-occupancy exception. Where facilities will not be used by women, urinals may be substituted for water closets, but the number of water closets may not be reduced below two-thirds of the minimum.",
      "exception_text": "Mobile crews and normally unattended locations are excepted when transportation is immediately available to nearby facilities meeting the standard.",
      "source_agency": "U.S. Occupational Safety and Health Administration",
      "source_title": "29 CFR 1910.141 — Sanitation",
      "source_url": "https://www.osha.gov/laws-regs/regulations/standardnumber/1910/1910.141",
      "source_document_date": "",
      "verification_date": "2026-07-27",
      "verification_tier": "★",
      "source_text_note": "Table J-1 bands do not overlap; counts are per sex and based on the maximum number present at one time on a regular shift."
    },
    {
      "record_id": "general-industry-07",
      "dataset_version": "1.0.0",
      "jurisdiction_level": "Federal",
      "jurisdiction_name": "United States",
      "workplace_category": "General industry / permanent workplaces",
      "standard_number": "29 CFR 1910.141",
      "requirement_type": "privacy_lock",
      "requirement_text": "Each water closet must occupy a separate compartment that assures privacy. A single-occupancy room may serve all sexes only if it can be locked from the inside and contains at least one water closet.",
      "employee_scope_text": "Permanent places of employment. “Number of employees” means the maximum number present at any one time on a regular shift; Table J-1 is calculated per sex.",
      "minimum_facility_text": "Per sex: 1–15: 1 water closet; 16–35: 2; 36–55: 3; 56–80: 4; 81–110: 5; 111–150: 6; over 150: 1 additional fixture per additional 40 employees.",
      "portable_facility_status": "Portable substitution may be treated as a de minimis departure only under the conditions described in OSHA’s May 18, 1999 interpretation, including impracticability of water carriage or temporary installation and adequate access, lighting, security, temperature control when needed, maintenance, and servicing.",
      "access_rule": "Mobile crews and normally unattended locations are excepted only when transportation is immediately available to nearby compliant toilet facilities. OSHA requires prompt access and reasonable restrictions.",
      "service_rule": "Toilet rooms and facilities must be sanitary. Under the 1999 portable-substitution interpretation, units must be well maintained and serviced.",
      "washing_rule": "Lavatories must have hot and cold or tepid running water, cleansing agents, and individual drying facilities, subject to the mobile-crew and unattended-location exception.",
      "privacy_lock_rule": "Each water closet must occupy a separate compartment that assures privacy. A single-occupancy room may serve all sexes only if it can be locked from the inside and contains at least one water closet.",
      "sex_separation_rule": "Separate toilet rooms must be provided for each sex, subject to the lockable single-occupancy exception. Where facilities will not be used by women, urinals may be substituted for water closets, but the number of water closets may not be reduced below two-thirds of the minimum.",
      "exception_text": "Mobile crews and normally unattended locations are excepted when transportation is immediately available to nearby facilities meeting the standard.",
      "source_agency": "U.S. Occupational Safety and Health Administration",
      "source_title": "29 CFR 1910.141 — Sanitation",
      "source_url": "https://www.osha.gov/laws-regs/regulations/standardnumber/1910/1910.141",
      "source_document_date": "",
      "verification_date": "2026-07-27",
      "verification_tier": "★",
      "source_text_note": "Table J-1 bands do not overlap; counts are per sex and based on the maximum number present at one time on a regular shift."
    },
    {
      "record_id": "general-industry-08",
      "dataset_version": "1.0.0",
      "jurisdiction_level": "Federal",
      "jurisdiction_name": "United States",
      "workplace_category": "General industry / permanent workplaces",
      "standard_number": "29 CFR 1910.141",
      "requirement_type": "sex_separation",
      "requirement_text": "Separate toilet rooms must be provided for each sex, subject to the lockable single-occupancy exception. Where facilities will not be used by women, urinals may be substituted for water closets, but the number of water closets may not be reduced below two-thirds of the minimum.",
      "employee_scope_text": "Permanent places of employment. “Number of employees” means the maximum number present at any one time on a regular shift; Table J-1 is calculated per sex.",
      "minimum_facility_text": "Per sex: 1–15: 1 water closet; 16–35: 2; 36–55: 3; 56–80: 4; 81–110: 5; 111–150: 6; over 150: 1 additional fixture per additional 40 employees.",
      "portable_facility_status": "Portable substitution may be treated as a de minimis departure only under the conditions described in OSHA’s May 18, 1999 interpretation, including impracticability of water carriage or temporary installation and adequate access, lighting, security, temperature control when needed, maintenance, and servicing.",
      "access_rule": "Mobile crews and normally unattended locations are excepted only when transportation is immediately available to nearby compliant toilet facilities. OSHA requires prompt access and reasonable restrictions.",
      "service_rule": "Toilet rooms and facilities must be sanitary. Under the 1999 portable-substitution interpretation, units must be well maintained and serviced.",
      "washing_rule": "Lavatories must have hot and cold or tepid running water, cleansing agents, and individual drying facilities, subject to the mobile-crew and unattended-location exception.",
      "privacy_lock_rule": "Each water closet must occupy a separate compartment that assures privacy. A single-occupancy room may serve all sexes only if it can be locked from the inside and contains at least one water closet.",
      "sex_separation_rule": "Separate toilet rooms must be provided for each sex, subject to the lockable single-occupancy exception. Where facilities will not be used by women, urinals may be substituted for water closets, but the number of water closets may not be reduced below two-thirds of the minimum.",
      "exception_text": "Mobile crews and normally unattended locations are excepted when transportation is immediately available to nearby facilities meeting the standard.",
      "source_agency": "U.S. Occupational Safety and Health Administration",
      "source_title": "29 CFR 1910.141 — Sanitation",
      "source_url": "https://www.osha.gov/laws-regs/regulations/standardnumber/1910/1910.141",
      "source_document_date": "",
      "verification_date": "2026-07-27",
      "verification_tier": "★",
      "source_text_note": "Table J-1 bands do not overlap; counts are per sex and based on the maximum number present at one time on a regular shift."
    },
    {
      "record_id": "general-industry-09",
      "dataset_version": "1.0.0",
      "jurisdiction_level": "Federal",
      "jurisdiction_name": "United States",
      "workplace_category": "General industry / permanent workplaces",
      "standard_number": "29 CFR 1910.141",
      "requirement_type": "exceptions",
      "requirement_text": "Mobile crews and normally unattended locations are excepted when transportation is immediately available to nearby facilities meeting the standard.",
      "employee_scope_text": "Permanent places of employment. “Number of employees” means the maximum number present at any one time on a regular shift; Table J-1 is calculated per sex.",
      "minimum_facility_text": "Per sex: 1–15: 1 water closet; 16–35: 2; 36–55: 3; 56–80: 4; 81–110: 5; 111–150: 6; over 150: 1 additional fixture per additional 40 employees.",
      "portable_facility_status": "Portable substitution may be treated as a de minimis departure only under the conditions described in OSHA’s May 18, 1999 interpretation, including impracticability of water carriage or temporary installation and adequate access, lighting, security, temperature control when needed, maintenance, and servicing.",
      "access_rule": "Mobile crews and normally unattended locations are excepted only when transportation is immediately available to nearby compliant toilet facilities. OSHA requires prompt access and reasonable restrictions.",
      "service_rule": "Toilet rooms and facilities must be sanitary. Under the 1999 portable-substitution interpretation, units must be well maintained and serviced.",
      "washing_rule": "Lavatories must have hot and cold or tepid running water, cleansing agents, and individual drying facilities, subject to the mobile-crew and unattended-location exception.",
      "privacy_lock_rule": "Each water closet must occupy a separate compartment that assures privacy. A single-occupancy room may serve all sexes only if it can be locked from the inside and contains at least one water closet.",
      "sex_separation_rule": "Separate toilet rooms must be provided for each sex, subject to the lockable single-occupancy exception. Where facilities will not be used by women, urinals may be substituted for water closets, but the number of water closets may not be reduced below two-thirds of the minimum.",
      "exception_text": "Mobile crews and normally unattended locations are excepted when transportation is immediately available to nearby facilities meeting the standard.",
      "source_agency": "U.S. Occupational Safety and Health Administration",
      "source_title": "29 CFR 1910.141 — Sanitation",
      "source_url": "https://www.osha.gov/laws-regs/regulations/standardnumber/1910/1910.141",
      "source_document_date": "",
      "verification_date": "2026-07-27",
      "verification_tier": "★",
      "source_text_note": "Table J-1 bands do not overlap; counts are per sex and based on the maximum number present at one time on a regular shift."
    },
    {
      "record_id": "agriculture-01",
      "dataset_version": "1.0.0",
      "jurisdiction_level": "Federal",
      "jurisdiction_name": "United States",
      "workplace_category": "Agricultural hand-labor field operations",
      "standard_number": "29 CFR 1928.110",
      "requirement_type": "employee_count",
      "requirement_text": "One toilet facility and one handwashing facility for each 20 employees or fraction thereof.",
      "employee_scope_text": "Applies when 11 or more employees are engaged in hand-labor operations in the field on a given day.",
      "minimum_facility_text": "One toilet facility and one handwashing facility for each 20 employees or fraction thereof.",
      "portable_facility_status": "The definition of toilet facility includes fixed or portable biological toilets, chemical toilets, flush toilets, combustion toilets, and sanitary privies.",
      "access_rule": "Toilet and handwashing facilities must be accessibly located and in close proximity to each other; generally within a one-quarter-mile walk, or at the closest point of vehicular access where terrain makes that infeasible.",
      "service_rule": "Facilities must be maintained clean, sanitary, and operational. Toilet paper must be provided in a suitable holder.",
      "washing_rule": "One handwashing facility per 20 employees or fraction, with potable water, soap, and single-use towels.",
      "privacy_lock_rule": "Toilet facilities must have ventilation, screening, a self-closing door, an inside latch, and privacy.",
      "sex_separation_rule": "The standard does not state a per-sex facility count.",
      "exception_text": "The requirements do not apply to employees performing field work for three hours or less during the day, including transportation time to and from the field.",
      "source_agency": "U.S. Occupational Safety and Health Administration",
      "source_title": "29 CFR 1928.110 — Field Sanitation",
      "source_url": "https://www.osha.gov/laws-regs/regulations/standardnumber/1928/1928.110",
      "source_document_date": "",
      "verification_date": "2026-07-27",
      "verification_tier": "★",
      "source_text_note": "The rule expressly includes “or fraction thereof,” unlike federal construction Table D-1."
    },
    {
      "record_id": "agriculture-02",
      "dataset_version": "1.0.0",
      "jurisdiction_level": "Federal",
      "jurisdiction_name": "United States",
      "workplace_category": "Agricultural hand-labor field operations",
      "standard_number": "29 CFR 1928.110",
      "requirement_type": "denominator",
      "requirement_text": "Applies when 11 or more employees are engaged in hand-labor operations in the field on a given day.",
      "employee_scope_text": "Applies when 11 or more employees are engaged in hand-labor operations in the field on a given day.",
      "minimum_facility_text": "One toilet facility and one handwashing facility for each 20 employees or fraction thereof.",
      "portable_facility_status": "The definition of toilet facility includes fixed or portable biological toilets, chemical toilets, flush toilets, combustion toilets, and sanitary privies.",
      "access_rule": "Toilet and handwashing facilities must be accessibly located and in close proximity to each other; generally within a one-quarter-mile walk, or at the closest point of vehicular access where terrain makes that infeasible.",
      "service_rule": "Facilities must be maintained clean, sanitary, and operational. Toilet paper must be provided in a suitable holder.",
      "washing_rule": "One handwashing facility per 20 employees or fraction, with potable water, soap, and single-use towels.",
      "privacy_lock_rule": "Toilet facilities must have ventilation, screening, a self-closing door, an inside latch, and privacy.",
      "sex_separation_rule": "The standard does not state a per-sex facility count.",
      "exception_text": "The requirements do not apply to employees performing field work for three hours or less during the day, including transportation time to and from the field.",
      "source_agency": "U.S. Occupational Safety and Health Administration",
      "source_title": "29 CFR 1928.110 — Field Sanitation",
      "source_url": "https://www.osha.gov/laws-regs/regulations/standardnumber/1928/1928.110",
      "source_document_date": "",
      "verification_date": "2026-07-27",
      "verification_tier": "★",
      "source_text_note": "The rule expressly includes “or fraction thereof,” unlike federal construction Table D-1."
    },
    {
      "record_id": "agriculture-03",
      "dataset_version": "1.0.0",
      "jurisdiction_level": "Federal",
      "jurisdiction_name": "United States",
      "workplace_category": "Agricultural hand-labor field operations",
      "standard_number": "29 CFR 1928.110",
      "requirement_type": "portable_units",
      "requirement_text": "The definition of toilet facility includes fixed or portable biological toilets, chemical toilets, flush toilets, combustion toilets, and sanitary privies.",
      "employee_scope_text": "Applies when 11 or more employees are engaged in hand-labor operations in the field on a given day.",
      "minimum_facility_text": "One toilet facility and one handwashing facility for each 20 employees or fraction thereof.",
      "portable_facility_status": "The definition of toilet facility includes fixed or portable biological toilets, chemical toilets, flush toilets, combustion toilets, and sanitary privies.",
      "access_rule": "Toilet and handwashing facilities must be accessibly located and in close proximity to each other; generally within a one-quarter-mile walk, or at the closest point of vehicular access where terrain makes that infeasible.",
      "service_rule": "Facilities must be maintained clean, sanitary, and operational. Toilet paper must be provided in a suitable holder.",
      "washing_rule": "One handwashing facility per 20 employees or fraction, with potable water, soap, and single-use towels.",
      "privacy_lock_rule": "Toilet facilities must have ventilation, screening, a self-closing door, an inside latch, and privacy.",
      "sex_separation_rule": "The standard does not state a per-sex facility count.",
      "exception_text": "The requirements do not apply to employees performing field work for three hours or less during the day, including transportation time to and from the field.",
      "source_agency": "U.S. Occupational Safety and Health Administration",
      "source_title": "29 CFR 1928.110 — Field Sanitation",
      "source_url": "https://www.osha.gov/laws-regs/regulations/standardnumber/1928/1928.110",
      "source_document_date": "",
      "verification_date": "2026-07-27",
      "verification_tier": "★",
      "source_text_note": "The rule expressly includes “or fraction thereof,” unlike federal construction Table D-1."
    },
    {
      "record_id": "agriculture-04",
      "dataset_version": "1.0.0",
      "jurisdiction_level": "Federal",
      "jurisdiction_name": "United States",
      "workplace_category": "Agricultural hand-labor field operations",
      "standard_number": "29 CFR 1928.110",
      "requirement_type": "access",
      "requirement_text": "Toilet and handwashing facilities must be accessibly located and in close proximity to each other; generally within a one-quarter-mile walk, or at the closest point of vehicular access where terrain makes that infeasible.",
      "employee_scope_text": "Applies when 11 or more employees are engaged in hand-labor operations in the field on a given day.",
      "minimum_facility_text": "One toilet facility and one handwashing facility for each 20 employees or fraction thereof.",
      "portable_facility_status": "The definition of toilet facility includes fixed or portable biological toilets, chemical toilets, flush toilets, combustion toilets, and sanitary privies.",
      "access_rule": "Toilet and handwashing facilities must be accessibly located and in close proximity to each other; generally within a one-quarter-mile walk, or at the closest point of vehicular access where terrain makes that infeasible.",
      "service_rule": "Facilities must be maintained clean, sanitary, and operational. Toilet paper must be provided in a suitable holder.",
      "washing_rule": "One handwashing facility per 20 employees or fraction, with potable water, soap, and single-use towels.",
      "privacy_lock_rule": "Toilet facilities must have ventilation, screening, a self-closing door, an inside latch, and privacy.",
      "sex_separation_rule": "The standard does not state a per-sex facility count.",
      "exception_text": "The requirements do not apply to employees performing field work for three hours or less during the day, including transportation time to and from the field.",
      "source_agency": "U.S. Occupational Safety and Health Administration",
      "source_title": "29 CFR 1928.110 — Field Sanitation",
      "source_url": "https://www.osha.gov/laws-regs/regulations/standardnumber/1928/1928.110",
      "source_document_date": "",
      "verification_date": "2026-07-27",
      "verification_tier": "★",
      "source_text_note": "The rule expressly includes “or fraction thereof,” unlike federal construction Table D-1."
    },
    {
      "record_id": "agriculture-05",
      "dataset_version": "1.0.0",
      "jurisdiction_level": "Federal",
      "jurisdiction_name": "United States",
      "workplace_category": "Agricultural hand-labor field operations",
      "standard_number": "29 CFR 1928.110",
      "requirement_type": "servicing",
      "requirement_text": "Facilities must be maintained clean, sanitary, and operational. Toilet paper must be provided in a suitable holder.",
      "employee_scope_text": "Applies when 11 or more employees are engaged in hand-labor operations in the field on a given day.",
      "minimum_facility_text": "One toilet facility and one handwashing facility for each 20 employees or fraction thereof.",
      "portable_facility_status": "The definition of toilet facility includes fixed or portable biological toilets, chemical toilets, flush toilets, combustion toilets, and sanitary privies.",
      "access_rule": "Toilet and handwashing facilities must be accessibly located and in close proximity to each other; generally within a one-quarter-mile walk, or at the closest point of vehicular access where terrain makes that infeasible.",
      "service_rule": "Facilities must be maintained clean, sanitary, and operational. Toilet paper must be provided in a suitable holder.",
      "washing_rule": "One handwashing facility per 20 employees or fraction, with potable water, soap, and single-use towels.",
      "privacy_lock_rule": "Toilet facilities must have ventilation, screening, a self-closing door, an inside latch, and privacy.",
      "sex_separation_rule": "The standard does not state a per-sex facility count.",
      "exception_text": "The requirements do not apply to employees performing field work for three hours or less during the day, including transportation time to and from the field.",
      "source_agency": "U.S. Occupational Safety and Health Administration",
      "source_title": "29 CFR 1928.110 — Field Sanitation",
      "source_url": "https://www.osha.gov/laws-regs/regulations/standardnumber/1928/1928.110",
      "source_document_date": "",
      "verification_date": "2026-07-27",
      "verification_tier": "★",
      "source_text_note": "The rule expressly includes “or fraction thereof,” unlike federal construction Table D-1."
    },
    {
      "record_id": "agriculture-06",
      "dataset_version": "1.0.0",
      "jurisdiction_level": "Federal",
      "jurisdiction_name": "United States",
      "workplace_category": "Agricultural hand-labor field operations",
      "standard_number": "29 CFR 1928.110",
      "requirement_type": "washing",
      "requirement_text": "One handwashing facility per 20 employees or fraction, with potable water, soap, and single-use towels.",
      "employee_scope_text": "Applies when 11 or more employees are engaged in hand-labor operations in the field on a given day.",
      "minimum_facility_text": "One toilet facility and one handwashing facility for each 20 employees or fraction thereof.",
      "portable_facility_status": "The definition of toilet facility includes fixed or portable biological toilets, chemical toilets, flush toilets, combustion toilets, and sanitary privies.",
      "access_rule": "Toilet and handwashing facilities must be accessibly located and in close proximity to each other; generally within a one-quarter-mile walk, or at the closest point of vehicular access where terrain makes that infeasible.",
      "service_rule": "Facilities must be maintained clean, sanitary, and operational. Toilet paper must be provided in a suitable holder.",
      "washing_rule": "One handwashing facility per 20 employees or fraction, with potable water, soap, and single-use towels.",
      "privacy_lock_rule": "Toilet facilities must have ventilation, screening, a self-closing door, an inside latch, and privacy.",
      "sex_separation_rule": "The standard does not state a per-sex facility count.",
      "exception_text": "The requirements do not apply to employees performing field work for three hours or less during the day, including transportation time to and from the field.",
      "source_agency": "U.S. Occupational Safety and Health Administration",
      "source_title": "29 CFR 1928.110 — Field Sanitation",
      "source_url": "https://www.osha.gov/laws-regs/regulations/standardnumber/1928/1928.110",
      "source_document_date": "",
      "verification_date": "2026-07-27",
      "verification_tier": "★",
      "source_text_note": "The rule expressly includes “or fraction thereof,” unlike federal construction Table D-1."
    },
    {
      "record_id": "agriculture-07",
      "dataset_version": "1.0.0",
      "jurisdiction_level": "Federal",
      "jurisdiction_name": "United States",
      "workplace_category": "Agricultural hand-labor field operations",
      "standard_number": "29 CFR 1928.110",
      "requirement_type": "privacy_lock",
      "requirement_text": "Toilet facilities must have ventilation, screening, a self-closing door, an inside latch, and privacy.",
      "employee_scope_text": "Applies when 11 or more employees are engaged in hand-labor operations in the field on a given day.",
      "minimum_facility_text": "One toilet facility and one handwashing facility for each 20 employees or fraction thereof.",
      "portable_facility_status": "The definition of toilet facility includes fixed or portable biological toilets, chemical toilets, flush toilets, combustion toilets, and sanitary privies.",
      "access_rule": "Toilet and handwashing facilities must be accessibly located and in close proximity to each other; generally within a one-quarter-mile walk, or at the closest point of vehicular access where terrain makes that infeasible.",
      "service_rule": "Facilities must be maintained clean, sanitary, and operational. Toilet paper must be provided in a suitable holder.",
      "washing_rule": "One handwashing facility per 20 employees or fraction, with potable water, soap, and single-use towels.",
      "privacy_lock_rule": "Toilet facilities must have ventilation, screening, a self-closing door, an inside latch, and privacy.",
      "sex_separation_rule": "The standard does not state a per-sex facility count.",
      "exception_text": "The requirements do not apply to employees performing field work for three hours or less during the day, including transportation time to and from the field.",
      "source_agency": "U.S. Occupational Safety and Health Administration",
      "source_title": "29 CFR 1928.110 — Field Sanitation",
      "source_url": "https://www.osha.gov/laws-regs/regulations/standardnumber/1928/1928.110",
      "source_document_date": "",
      "verification_date": "2026-07-27",
      "verification_tier": "★",
      "source_text_note": "The rule expressly includes “or fraction thereof,” unlike federal construction Table D-1."
    },
    {
      "record_id": "agriculture-08",
      "dataset_version": "1.0.0",
      "jurisdiction_level": "Federal",
      "jurisdiction_name": "United States",
      "workplace_category": "Agricultural hand-labor field operations",
      "standard_number": "29 CFR 1928.110",
      "requirement_type": "sex_separation",
      "requirement_text": "The standard does not state a per-sex facility count.",
      "employee_scope_text": "Applies when 11 or more employees are engaged in hand-labor operations in the field on a given day.",
      "minimum_facility_text": "One toilet facility and one handwashing facility for each 20 employees or fraction thereof.",
      "portable_facility_status": "The definition of toilet facility includes fixed or portable biological toilets, chemical toilets, flush toilets, combustion toilets, and sanitary privies.",
      "access_rule": "Toilet and handwashing facilities must be accessibly located and in close proximity to each other; generally within a one-quarter-mile walk, or at the closest point of vehicular access where terrain makes that infeasible.",
      "service_rule": "Facilities must be maintained clean, sanitary, and operational. Toilet paper must be provided in a suitable holder.",
      "washing_rule": "One handwashing facility per 20 employees or fraction, with potable water, soap, and single-use towels.",
      "privacy_lock_rule": "Toilet facilities must have ventilation, screening, a self-closing door, an inside latch, and privacy.",
      "sex_separation_rule": "The standard does not state a per-sex facility count.",
      "exception_text": "The requirements do not apply to employees performing field work for three hours or less during the day, including transportation time to and from the field.",
      "source_agency": "U.S. Occupational Safety and Health Administration",
      "source_title": "29 CFR 1928.110 — Field Sanitation",
      "source_url": "https://www.osha.gov/laws-regs/regulations/standardnumber/1928/1928.110",
      "source_document_date": "",
      "verification_date": "2026-07-27",
      "verification_tier": "★",
      "source_text_note": "The rule expressly includes “or fraction thereof,” unlike federal construction Table D-1."
    },
    {
      "record_id": "agriculture-09",
      "dataset_version": "1.0.0",
      "jurisdiction_level": "Federal",
      "jurisdiction_name": "United States",
      "workplace_category": "Agricultural hand-labor field operations",
      "standard_number": "29 CFR 1928.110",
      "requirement_type": "exceptions",
      "requirement_text": "The requirements do not apply to employees performing field work for three hours or less during the day, including transportation time to and from the field.",
      "employee_scope_text": "Applies when 11 or more employees are engaged in hand-labor operations in the field on a given day.",
      "minimum_facility_text": "One toilet facility and one handwashing facility for each 20 employees or fraction thereof.",
      "portable_facility_status": "The definition of toilet facility includes fixed or portable biological toilets, chemical toilets, flush toilets, combustion toilets, and sanitary privies.",
      "access_rule": "Toilet and handwashing facilities must be accessibly located and in close proximity to each other; generally within a one-quarter-mile walk, or at the closest point of vehicular access where terrain makes that infeasible.",
      "service_rule": "Facilities must be maintained clean, sanitary, and operational. Toilet paper must be provided in a suitable holder.",
      "washing_rule": "One handwashing facility per 20 employees or fraction, with potable water, soap, and single-use towels.",
      "privacy_lock_rule": "Toilet facilities must have ventilation, screening, a self-closing door, an inside latch, and privacy.",
      "sex_separation_rule": "The standard does not state a per-sex facility count.",
      "exception_text": "The requirements do not apply to employees performing field work for three hours or less during the day, including transportation time to and from the field.",
      "source_agency": "U.S. Occupational Safety and Health Administration",
      "source_title": "29 CFR 1928.110 — Field Sanitation",
      "source_url": "https://www.osha.gov/laws-regs/regulations/standardnumber/1928/1928.110",
      "source_document_date": "",
      "verification_date": "2026-07-27",
      "verification_tier": "★",
      "source_text_note": "The rule expressly includes “or fraction thereof,” unlike federal construction Table D-1."
    },
    {
      "record_id": "shipyard-01",
      "dataset_version": "1.0.0",
      "jurisdiction_level": "Federal",
      "jurisdiction_name": "United States",
      "workplace_category": "Shipyard employment",
      "standard_number": "29 CFR 1915.88",
      "requirement_type": "employee_count",
      "requirement_text": "Per sex: 1–15: 1; 16–35: 2; 36–55: 3; 56–80: 4; 81–110: 5; 111–150: 6; over 150: 1 additional toilet per additional 40 employees.",
      "employee_scope_text": "Maximum number of employees of each sex present at the worksite at any one time during a workshift.",
      "minimum_facility_text": "Per sex: 1–15: 1; 16–35: 2; 36–55: 3; 56–80: 4; 81–110: 5; 111–150: 6; over 150: 1 additional toilet per additional 40 employees.",
      "portable_facility_status": "Portable toilets may be used only when the employer demonstrates that sewered toilets are not feasible or when the workforce temporarily increases for a short duration. Each portable toilet must be vented and lit as necessary.",
      "access_rule": "The employer must provide adequate and readily accessible sanitation facilities.",
      "service_rule": "The employer must establish and implement a schedule for servicing, cleaning, and supplying each facility so it remains clean, sanitary, and serviceable.",
      "washing_rule": "Handwashing facilities must be at or adjacent to each toilet. They must use running water and soap or qualifying waterless agents capable of disinfecting or neutralizing relevant contaminants.",
      "privacy_lock_rule": "Privacy is required. A single-occupancy room may serve all sexes only if it can be locked from the inside and contains at least one toilet.",
      "sex_separation_rule": "Separate facilities are required for each sex, subject to the lockable single-occupancy exception. Male-only urinal substitution may not reduce toilets below two-thirds of the minimum.",
      "exception_text": "Normally unattended worksites and mobile crews are excepted when immediately available transportation leads to readily accessible, compliant facilities.",
      "source_agency": "U.S. Occupational Safety and Health Administration",
      "source_title": "29 CFR 1915.88 — Sanitation",
      "source_url": "https://www.osha.gov/laws-regs/regulations/standardnumber/1915/1915.88",
      "source_document_date": "",
      "verification_date": "2026-07-27",
      "verification_tier": "★",
      "source_text_note": "Table F-2 bands do not overlap and are counted per sex."
    },
    {
      "record_id": "shipyard-02",
      "dataset_version": "1.0.0",
      "jurisdiction_level": "Federal",
      "jurisdiction_name": "United States",
      "workplace_category": "Shipyard employment",
      "standard_number": "29 CFR 1915.88",
      "requirement_type": "denominator",
      "requirement_text": "Maximum number of employees of each sex present at the worksite at any one time during a workshift.",
      "employee_scope_text": "Maximum number of employees of each sex present at the worksite at any one time during a workshift.",
      "minimum_facility_text": "Per sex: 1–15: 1; 16–35: 2; 36–55: 3; 56–80: 4; 81–110: 5; 111–150: 6; over 150: 1 additional toilet per additional 40 employees.",
      "portable_facility_status": "Portable toilets may be used only when the employer demonstrates that sewered toilets are not feasible or when the workforce temporarily increases for a short duration. Each portable toilet must be vented and lit as necessary.",
      "access_rule": "The employer must provide adequate and readily accessible sanitation facilities.",
      "service_rule": "The employer must establish and implement a schedule for servicing, cleaning, and supplying each facility so it remains clean, sanitary, and serviceable.",
      "washing_rule": "Handwashing facilities must be at or adjacent to each toilet. They must use running water and soap or qualifying waterless agents capable of disinfecting or neutralizing relevant contaminants.",
      "privacy_lock_rule": "Privacy is required. A single-occupancy room may serve all sexes only if it can be locked from the inside and contains at least one toilet.",
      "sex_separation_rule": "Separate facilities are required for each sex, subject to the lockable single-occupancy exception. Male-only urinal substitution may not reduce toilets below two-thirds of the minimum.",
      "exception_text": "Normally unattended worksites and mobile crews are excepted when immediately available transportation leads to readily accessible, compliant facilities.",
      "source_agency": "U.S. Occupational Safety and Health Administration",
      "source_title": "29 CFR 1915.88 — Sanitation",
      "source_url": "https://www.osha.gov/laws-regs/regulations/standardnumber/1915/1915.88",
      "source_document_date": "",
      "verification_date": "2026-07-27",
      "verification_tier": "★",
      "source_text_note": "Table F-2 bands do not overlap and are counted per sex."
    },
    {
      "record_id": "shipyard-03",
      "dataset_version": "1.0.0",
      "jurisdiction_level": "Federal",
      "jurisdiction_name": "United States",
      "workplace_category": "Shipyard employment",
      "standard_number": "29 CFR 1915.88",
      "requirement_type": "portable_units",
      "requirement_text": "Portable toilets may be used only when the employer demonstrates that sewered toilets are not feasible or when the workforce temporarily increases for a short duration. Each portable toilet must be vented and lit as necessary.",
      "employee_scope_text": "Maximum number of employees of each sex present at the worksite at any one time during a workshift.",
      "minimum_facility_text": "Per sex: 1–15: 1; 16–35: 2; 36–55: 3; 56–80: 4; 81–110: 5; 111–150: 6; over 150: 1 additional toilet per additional 40 employees.",
      "portable_facility_status": "Portable toilets may be used only when the employer demonstrates that sewered toilets are not feasible or when the workforce temporarily increases for a short duration. Each portable toilet must be vented and lit as necessary.",
      "access_rule": "The employer must provide adequate and readily accessible sanitation facilities.",
      "service_rule": "The employer must establish and implement a schedule for servicing, cleaning, and supplying each facility so it remains clean, sanitary, and serviceable.",
      "washing_rule": "Handwashing facilities must be at or adjacent to each toilet. They must use running water and soap or qualifying waterless agents capable of disinfecting or neutralizing relevant contaminants.",
      "privacy_lock_rule": "Privacy is required. A single-occupancy room may serve all sexes only if it can be locked from the inside and contains at least one toilet.",
      "sex_separation_rule": "Separate facilities are required for each sex, subject to the lockable single-occupancy exception. Male-only urinal substitution may not reduce toilets below two-thirds of the minimum.",
      "exception_text": "Normally unattended worksites and mobile crews are excepted when immediately available transportation leads to readily accessible, compliant facilities.",
      "source_agency": "U.S. Occupational Safety and Health Administration",
      "source_title": "29 CFR 1915.88 — Sanitation",
      "source_url": "https://www.osha.gov/laws-regs/regulations/standardnumber/1915/1915.88",
      "source_document_date": "",
      "verification_date": "2026-07-27",
      "verification_tier": "★",
      "source_text_note": "Table F-2 bands do not overlap and are counted per sex."
    },
    {
      "record_id": "shipyard-04",
      "dataset_version": "1.0.0",
      "jurisdiction_level": "Federal",
      "jurisdiction_name": "United States",
      "workplace_category": "Shipyard employment",
      "standard_number": "29 CFR 1915.88",
      "requirement_type": "access",
      "requirement_text": "The employer must provide adequate and readily accessible sanitation facilities.",
      "employee_scope_text": "Maximum number of employees of each sex present at the worksite at any one time during a workshift.",
      "minimum_facility_text": "Per sex: 1–15: 1; 16–35: 2; 36–55: 3; 56–80: 4; 81–110: 5; 111–150: 6; over 150: 1 additional toilet per additional 40 employees.",
      "portable_facility_status": "Portable toilets may be used only when the employer demonstrates that sewered toilets are not feasible or when the workforce temporarily increases for a short duration. Each portable toilet must be vented and lit as necessary.",
      "access_rule": "The employer must provide adequate and readily accessible sanitation facilities.",
      "service_rule": "The employer must establish and implement a schedule for servicing, cleaning, and supplying each facility so it remains clean, sanitary, and serviceable.",
      "washing_rule": "Handwashing facilities must be at or adjacent to each toilet. They must use running water and soap or qualifying waterless agents capable of disinfecting or neutralizing relevant contaminants.",
      "privacy_lock_rule": "Privacy is required. A single-occupancy room may serve all sexes only if it can be locked from the inside and contains at least one toilet.",
      "sex_separation_rule": "Separate facilities are required for each sex, subject to the lockable single-occupancy exception. Male-only urinal substitution may not reduce toilets below two-thirds of the minimum.",
      "exception_text": "Normally unattended worksites and mobile crews are excepted when immediately available transportation leads to readily accessible, compliant facilities.",
      "source_agency": "U.S. Occupational Safety and Health Administration",
      "source_title": "29 CFR 1915.88 — Sanitation",
      "source_url": "https://www.osha.gov/laws-regs/regulations/standardnumber/1915/1915.88",
      "source_document_date": "",
      "verification_date": "2026-07-27",
      "verification_tier": "★",
      "source_text_note": "Table F-2 bands do not overlap and are counted per sex."
    },
    {
      "record_id": "shipyard-05",
      "dataset_version": "1.0.0",
      "jurisdiction_level": "Federal",
      "jurisdiction_name": "United States",
      "workplace_category": "Shipyard employment",
      "standard_number": "29 CFR 1915.88",
      "requirement_type": "servicing",
      "requirement_text": "The employer must establish and implement a schedule for servicing, cleaning, and supplying each facility so it remains clean, sanitary, and serviceable.",
      "employee_scope_text": "Maximum number of employees of each sex present at the worksite at any one time during a workshift.",
      "minimum_facility_text": "Per sex: 1–15: 1; 16–35: 2; 36–55: 3; 56–80: 4; 81–110: 5; 111–150: 6; over 150: 1 additional toilet per additional 40 employees.",
      "portable_facility_status": "Portable toilets may be used only when the employer demonstrates that sewered toilets are not feasible or when the workforce temporarily increases for a short duration. Each portable toilet must be vented and lit as necessary.",
      "access_rule": "The employer must provide adequate and readily accessible sanitation facilities.",
      "service_rule": "The employer must establish and implement a schedule for servicing, cleaning, and supplying each facility so it remains clean, sanitary, and serviceable.",
      "washing_rule": "Handwashing facilities must be at or adjacent to each toilet. They must use running water and soap or qualifying waterless agents capable of disinfecting or neutralizing relevant contaminants.",
      "privacy_lock_rule": "Privacy is required. A single-occupancy room may serve all sexes only if it can be locked from the inside and contains at least one toilet.",
      "sex_separation_rule": "Separate facilities are required for each sex, subject to the lockable single-occupancy exception. Male-only urinal substitution may not reduce toilets below two-thirds of the minimum.",
      "exception_text": "Normally unattended worksites and mobile crews are excepted when immediately available transportation leads to readily accessible, compliant facilities.",
      "source_agency": "U.S. Occupational Safety and Health Administration",
      "source_title": "29 CFR 1915.88 — Sanitation",
      "source_url": "https://www.osha.gov/laws-regs/regulations/standardnumber/1915/1915.88",
      "source_document_date": "",
      "verification_date": "2026-07-27",
      "verification_tier": "★",
      "source_text_note": "Table F-2 bands do not overlap and are counted per sex."
    },
    {
      "record_id": "shipyard-06",
      "dataset_version": "1.0.0",
      "jurisdiction_level": "Federal",
      "jurisdiction_name": "United States",
      "workplace_category": "Shipyard employment",
      "standard_number": "29 CFR 1915.88",
      "requirement_type": "washing",
      "requirement_text": "Handwashing facilities must be at or adjacent to each toilet. They must use running water and soap or qualifying waterless agents capable of disinfecting or neutralizing relevant contaminants.",
      "employee_scope_text": "Maximum number of employees of each sex present at the worksite at any one time during a workshift.",
      "minimum_facility_text": "Per sex: 1–15: 1; 16–35: 2; 36–55: 3; 56–80: 4; 81–110: 5; 111–150: 6; over 150: 1 additional toilet per additional 40 employees.",
      "portable_facility_status": "Portable toilets may be used only when the employer demonstrates that sewered toilets are not feasible or when the workforce temporarily increases for a short duration. Each portable toilet must be vented and lit as necessary.",
      "access_rule": "The employer must provide adequate and readily accessible sanitation facilities.",
      "service_rule": "The employer must establish and implement a schedule for servicing, cleaning, and supplying each facility so it remains clean, sanitary, and serviceable.",
      "washing_rule": "Handwashing facilities must be at or adjacent to each toilet. They must use running water and soap or qualifying waterless agents capable of disinfecting or neutralizing relevant contaminants.",
      "privacy_lock_rule": "Privacy is required. A single-occupancy room may serve all sexes only if it can be locked from the inside and contains at least one toilet.",
      "sex_separation_rule": "Separate facilities are required for each sex, subject to the lockable single-occupancy exception. Male-only urinal substitution may not reduce toilets below two-thirds of the minimum.",
      "exception_text": "Normally unattended worksites and mobile crews are excepted when immediately available transportation leads to readily accessible, compliant facilities.",
      "source_agency": "U.S. Occupational Safety and Health Administration",
      "source_title": "29 CFR 1915.88 — Sanitation",
      "source_url": "https://www.osha.gov/laws-regs/regulations/standardnumber/1915/1915.88",
      "source_document_date": "",
      "verification_date": "2026-07-27",
      "verification_tier": "★",
      "source_text_note": "Table F-2 bands do not overlap and are counted per sex."
    },
    {
      "record_id": "shipyard-07",
      "dataset_version": "1.0.0",
      "jurisdiction_level": "Federal",
      "jurisdiction_name": "United States",
      "workplace_category": "Shipyard employment",
      "standard_number": "29 CFR 1915.88",
      "requirement_type": "privacy_lock",
      "requirement_text": "Privacy is required. A single-occupancy room may serve all sexes only if it can be locked from the inside and contains at least one toilet.",
      "employee_scope_text": "Maximum number of employees of each sex present at the worksite at any one time during a workshift.",
      "minimum_facility_text": "Per sex: 1–15: 1; 16–35: 2; 36–55: 3; 56–80: 4; 81–110: 5; 111–150: 6; over 150: 1 additional toilet per additional 40 employees.",
      "portable_facility_status": "Portable toilets may be used only when the employer demonstrates that sewered toilets are not feasible or when the workforce temporarily increases for a short duration. Each portable toilet must be vented and lit as necessary.",
      "access_rule": "The employer must provide adequate and readily accessible sanitation facilities.",
      "service_rule": "The employer must establish and implement a schedule for servicing, cleaning, and supplying each facility so it remains clean, sanitary, and serviceable.",
      "washing_rule": "Handwashing facilities must be at or adjacent to each toilet. They must use running water and soap or qualifying waterless agents capable of disinfecting or neutralizing relevant contaminants.",
      "privacy_lock_rule": "Privacy is required. A single-occupancy room may serve all sexes only if it can be locked from the inside and contains at least one toilet.",
      "sex_separation_rule": "Separate facilities are required for each sex, subject to the lockable single-occupancy exception. Male-only urinal substitution may not reduce toilets below two-thirds of the minimum.",
      "exception_text": "Normally unattended worksites and mobile crews are excepted when immediately available transportation leads to readily accessible, compliant facilities.",
      "source_agency": "U.S. Occupational Safety and Health Administration",
      "source_title": "29 CFR 1915.88 — Sanitation",
      "source_url": "https://www.osha.gov/laws-regs/regulations/standardnumber/1915/1915.88",
      "source_document_date": "",
      "verification_date": "2026-07-27",
      "verification_tier": "★",
      "source_text_note": "Table F-2 bands do not overlap and are counted per sex."
    },
    {
      "record_id": "shipyard-08",
      "dataset_version": "1.0.0",
      "jurisdiction_level": "Federal",
      "jurisdiction_name": "United States",
      "workplace_category": "Shipyard employment",
      "standard_number": "29 CFR 1915.88",
      "requirement_type": "sex_separation",
      "requirement_text": "Separate facilities are required for each sex, subject to the lockable single-occupancy exception. Male-only urinal substitution may not reduce toilets below two-thirds of the minimum.",
      "employee_scope_text": "Maximum number of employees of each sex present at the worksite at any one time during a workshift.",
      "minimum_facility_text": "Per sex: 1–15: 1; 16–35: 2; 36–55: 3; 56–80: 4; 81–110: 5; 111–150: 6; over 150: 1 additional toilet per additional 40 employees.",
      "portable_facility_status": "Portable toilets may be used only when the employer demonstrates that sewered toilets are not feasible or when the workforce temporarily increases for a short duration. Each portable toilet must be vented and lit as necessary.",
      "access_rule": "The employer must provide adequate and readily accessible sanitation facilities.",
      "service_rule": "The employer must establish and implement a schedule for servicing, cleaning, and supplying each facility so it remains clean, sanitary, and serviceable.",
      "washing_rule": "Handwashing facilities must be at or adjacent to each toilet. They must use running water and soap or qualifying waterless agents capable of disinfecting or neutralizing relevant contaminants.",
      "privacy_lock_rule": "Privacy is required. A single-occupancy room may serve all sexes only if it can be locked from the inside and contains at least one toilet.",
      "sex_separation_rule": "Separate facilities are required for each sex, subject to the lockable single-occupancy exception. Male-only urinal substitution may not reduce toilets below two-thirds of the minimum.",
      "exception_text": "Normally unattended worksites and mobile crews are excepted when immediately available transportation leads to readily accessible, compliant facilities.",
      "source_agency": "U.S. Occupational Safety and Health Administration",
      "source_title": "29 CFR 1915.88 — Sanitation",
      "source_url": "https://www.osha.gov/laws-regs/regulations/standardnumber/1915/1915.88",
      "source_document_date": "",
      "verification_date": "2026-07-27",
      "verification_tier": "★",
      "source_text_note": "Table F-2 bands do not overlap and are counted per sex."
    },
    {
      "record_id": "shipyard-09",
      "dataset_version": "1.0.0",
      "jurisdiction_level": "Federal",
      "jurisdiction_name": "United States",
      "workplace_category": "Shipyard employment",
      "standard_number": "29 CFR 1915.88",
      "requirement_type": "exceptions",
      "requirement_text": "Normally unattended worksites and mobile crews are excepted when immediately available transportation leads to readily accessible, compliant facilities.",
      "employee_scope_text": "Maximum number of employees of each sex present at the worksite at any one time during a workshift.",
      "minimum_facility_text": "Per sex: 1–15: 1; 16–35: 2; 36–55: 3; 56–80: 4; 81–110: 5; 111–150: 6; over 150: 1 additional toilet per additional 40 employees.",
      "portable_facility_status": "Portable toilets may be used only when the employer demonstrates that sewered toilets are not feasible or when the workforce temporarily increases for a short duration. Each portable toilet must be vented and lit as necessary.",
      "access_rule": "The employer must provide adequate and readily accessible sanitation facilities.",
      "service_rule": "The employer must establish and implement a schedule for servicing, cleaning, and supplying each facility so it remains clean, sanitary, and serviceable.",
      "washing_rule": "Handwashing facilities must be at or adjacent to each toilet. They must use running water and soap or qualifying waterless agents capable of disinfecting or neutralizing relevant contaminants.",
      "privacy_lock_rule": "Privacy is required. A single-occupancy room may serve all sexes only if it can be locked from the inside and contains at least one toilet.",
      "sex_separation_rule": "Separate facilities are required for each sex, subject to the lockable single-occupancy exception. Male-only urinal substitution may not reduce toilets below two-thirds of the minimum.",
      "exception_text": "Normally unattended worksites and mobile crews are excepted when immediately available transportation leads to readily accessible, compliant facilities.",
      "source_agency": "U.S. Occupational Safety and Health Administration",
      "source_title": "29 CFR 1915.88 — Sanitation",
      "source_url": "https://www.osha.gov/laws-regs/regulations/standardnumber/1915/1915.88",
      "source_document_date": "",
      "verification_date": "2026-07-27",
      "verification_tier": "★",
      "source_text_note": "Table F-2 bands do not overlap and are counted per sex."
    },
    {
      "record_id": "hazwoper-general-01",
      "dataset_version": "1.0.0",
      "jurisdiction_level": "Federal",
      "jurisdiction_name": "United States",
      "workplace_category": "HAZWOPER — general industry",
      "standard_number": "29 CFR 1910.120(n)",
      "requirement_type": "employee_count",
      "requirement_text": "20 or fewer: 1; more than 20 but fewer than 200: 1 toilet seat and 1 urinal per 40 workers; more than 200: 1 toilet seat and 1 urinal per 50 workers.",
      "employee_scope_text": "Employees at temporary hazardous-waste worksites covered by 29 CFR 1910.120(n).",
      "minimum_facility_text": "20 or fewer: 1; more than 20 but fewer than 200: 1 toilet seat and 1 urinal per 40 workers; more than 200: 1 toilet seat and 1 urinal per 50 workers.",
      "portable_facility_status": "Where no sanitary sewer is available, chemical, recirculating, combustion, or flush toilets are permitted unless prohibited by local codes.",
      "access_rule": "A mobile-crew exception applies when transportation is readily available to nearby toilet facilities.",
      "service_rule": "No fixed servicing interval is stated in paragraph (n).",
      "washing_rule": "Adequate washing facilities must be provided in near proximity where hazardous substances may be harmful, and the washing area must be in an area where exposures are below permissible limits and published exposure levels.",
      "privacy_lock_rule": "Doors entering toilet facilities must have entrance locks controlled from inside the facility.",
      "sex_separation_rule": "No sex-separation provision is stated in paragraph (n).",
      "exception_text": "Mobile crews with readily available transportation to nearby toilet facilities are excepted.",
      "source_agency": "U.S. Occupational Safety and Health Administration",
      "source_title": "29 CFR 1910.120 — Hazardous Waste Operations and Emergency Response",
      "source_url": "https://www.osha.gov/laws-regs/regulations/standardnumber/1910/1910.120",
      "source_document_date": "",
      "verification_date": "2026-07-27",
      "verification_tier": "★",
      "source_text_note": "Exactly 200 employees is not assigned to a printed row because the middle row is fewer than 200 and the final row is more than 200."
    },
    {
      "record_id": "hazwoper-general-02",
      "dataset_version": "1.0.0",
      "jurisdiction_level": "Federal",
      "jurisdiction_name": "United States",
      "workplace_category": "HAZWOPER — general industry",
      "standard_number": "29 CFR 1910.120(n)",
      "requirement_type": "denominator",
      "requirement_text": "Employees at temporary hazardous-waste worksites covered by 29 CFR 1910.120(n).",
      "employee_scope_text": "Employees at temporary hazardous-waste worksites covered by 29 CFR 1910.120(n).",
      "minimum_facility_text": "20 or fewer: 1; more than 20 but fewer than 200: 1 toilet seat and 1 urinal per 40 workers; more than 200: 1 toilet seat and 1 urinal per 50 workers.",
      "portable_facility_status": "Where no sanitary sewer is available, chemical, recirculating, combustion, or flush toilets are permitted unless prohibited by local codes.",
      "access_rule": "A mobile-crew exception applies when transportation is readily available to nearby toilet facilities.",
      "service_rule": "No fixed servicing interval is stated in paragraph (n).",
      "washing_rule": "Adequate washing facilities must be provided in near proximity where hazardous substances may be harmful, and the washing area must be in an area where exposures are below permissible limits and published exposure levels.",
      "privacy_lock_rule": "Doors entering toilet facilities must have entrance locks controlled from inside the facility.",
      "sex_separation_rule": "No sex-separation provision is stated in paragraph (n).",
      "exception_text": "Mobile crews with readily available transportation to nearby toilet facilities are excepted.",
      "source_agency": "U.S. Occupational Safety and Health Administration",
      "source_title": "29 CFR 1910.120 — Hazardous Waste Operations and Emergency Response",
      "source_url": "https://www.osha.gov/laws-regs/regulations/standardnumber/1910/1910.120",
      "source_document_date": "",
      "verification_date": "2026-07-27",
      "verification_tier": "★",
      "source_text_note": "Exactly 200 employees is not assigned to a printed row because the middle row is fewer than 200 and the final row is more than 200."
    },
    {
      "record_id": "hazwoper-general-03",
      "dataset_version": "1.0.0",
      "jurisdiction_level": "Federal",
      "jurisdiction_name": "United States",
      "workplace_category": "HAZWOPER — general industry",
      "standard_number": "29 CFR 1910.120(n)",
      "requirement_type": "portable_units",
      "requirement_text": "Where no sanitary sewer is available, chemical, recirculating, combustion, or flush toilets are permitted unless prohibited by local codes.",
      "employee_scope_text": "Employees at temporary hazardous-waste worksites covered by 29 CFR 1910.120(n).",
      "minimum_facility_text": "20 or fewer: 1; more than 20 but fewer than 200: 1 toilet seat and 1 urinal per 40 workers; more than 200: 1 toilet seat and 1 urinal per 50 workers.",
      "portable_facility_status": "Where no sanitary sewer is available, chemical, recirculating, combustion, or flush toilets are permitted unless prohibited by local codes.",
      "access_rule": "A mobile-crew exception applies when transportation is readily available to nearby toilet facilities.",
      "service_rule": "No fixed servicing interval is stated in paragraph (n).",
      "washing_rule": "Adequate washing facilities must be provided in near proximity where hazardous substances may be harmful, and the washing area must be in an area where exposures are below permissible limits and published exposure levels.",
      "privacy_lock_rule": "Doors entering toilet facilities must have entrance locks controlled from inside the facility.",
      "sex_separation_rule": "No sex-separation provision is stated in paragraph (n).",
      "exception_text": "Mobile crews with readily available transportation to nearby toilet facilities are excepted.",
      "source_agency": "U.S. Occupational Safety and Health Administration",
      "source_title": "29 CFR 1910.120 — Hazardous Waste Operations and Emergency Response",
      "source_url": "https://www.osha.gov/laws-regs/regulations/standardnumber/1910/1910.120",
      "source_document_date": "",
      "verification_date": "2026-07-27",
      "verification_tier": "★",
      "source_text_note": "Exactly 200 employees is not assigned to a printed row because the middle row is fewer than 200 and the final row is more than 200."
    },
    {
      "record_id": "hazwoper-general-04",
      "dataset_version": "1.0.0",
      "jurisdiction_level": "Federal",
      "jurisdiction_name": "United States",
      "workplace_category": "HAZWOPER — general industry",
      "standard_number": "29 CFR 1910.120(n)",
      "requirement_type": "access",
      "requirement_text": "A mobile-crew exception applies when transportation is readily available to nearby toilet facilities.",
      "employee_scope_text": "Employees at temporary hazardous-waste worksites covered by 29 CFR 1910.120(n).",
      "minimum_facility_text": "20 or fewer: 1; more than 20 but fewer than 200: 1 toilet seat and 1 urinal per 40 workers; more than 200: 1 toilet seat and 1 urinal per 50 workers.",
      "portable_facility_status": "Where no sanitary sewer is available, chemical, recirculating, combustion, or flush toilets are permitted unless prohibited by local codes.",
      "access_rule": "A mobile-crew exception applies when transportation is readily available to nearby toilet facilities.",
      "service_rule": "No fixed servicing interval is stated in paragraph (n).",
      "washing_rule": "Adequate washing facilities must be provided in near proximity where hazardous substances may be harmful, and the washing area must be in an area where exposures are below permissible limits and published exposure levels.",
      "privacy_lock_rule": "Doors entering toilet facilities must have entrance locks controlled from inside the facility.",
      "sex_separation_rule": "No sex-separation provision is stated in paragraph (n).",
      "exception_text": "Mobile crews with readily available transportation to nearby toilet facilities are excepted.",
      "source_agency": "U.S. Occupational Safety and Health Administration",
      "source_title": "29 CFR 1910.120 — Hazardous Waste Operations and Emergency Response",
      "source_url": "https://www.osha.gov/laws-regs/regulations/standardnumber/1910/1910.120",
      "source_document_date": "",
      "verification_date": "2026-07-27",
      "verification_tier": "★",
      "source_text_note": "Exactly 200 employees is not assigned to a printed row because the middle row is fewer than 200 and the final row is more than 200."
    },
    {
      "record_id": "hazwoper-general-05",
      "dataset_version": "1.0.0",
      "jurisdiction_level": "Federal",
      "jurisdiction_name": "United States",
      "workplace_category": "HAZWOPER — general industry",
      "standard_number": "29 CFR 1910.120(n)",
      "requirement_type": "servicing",
      "requirement_text": "No fixed servicing interval is stated in paragraph (n).",
      "employee_scope_text": "Employees at temporary hazardous-waste worksites covered by 29 CFR 1910.120(n).",
      "minimum_facility_text": "20 or fewer: 1; more than 20 but fewer than 200: 1 toilet seat and 1 urinal per 40 workers; more than 200: 1 toilet seat and 1 urinal per 50 workers.",
      "portable_facility_status": "Where no sanitary sewer is available, chemical, recirculating, combustion, or flush toilets are permitted unless prohibited by local codes.",
      "access_rule": "A mobile-crew exception applies when transportation is readily available to nearby toilet facilities.",
      "service_rule": "No fixed servicing interval is stated in paragraph (n).",
      "washing_rule": "Adequate washing facilities must be provided in near proximity where hazardous substances may be harmful, and the washing area must be in an area where exposures are below permissible limits and published exposure levels.",
      "privacy_lock_rule": "Doors entering toilet facilities must have entrance locks controlled from inside the facility.",
      "sex_separation_rule": "No sex-separation provision is stated in paragraph (n).",
      "exception_text": "Mobile crews with readily available transportation to nearby toilet facilities are excepted.",
      "source_agency": "U.S. Occupational Safety and Health Administration",
      "source_title": "29 CFR 1910.120 — Hazardous Waste Operations and Emergency Response",
      "source_url": "https://www.osha.gov/laws-regs/regulations/standardnumber/1910/1910.120",
      "source_document_date": "",
      "verification_date": "2026-07-27",
      "verification_tier": "★",
      "source_text_note": "Exactly 200 employees is not assigned to a printed row because the middle row is fewer than 200 and the final row is more than 200."
    },
    {
      "record_id": "hazwoper-general-06",
      "dataset_version": "1.0.0",
      "jurisdiction_level": "Federal",
      "jurisdiction_name": "United States",
      "workplace_category": "HAZWOPER — general industry",
      "standard_number": "29 CFR 1910.120(n)",
      "requirement_type": "washing",
      "requirement_text": "Adequate washing facilities must be provided in near proximity where hazardous substances may be harmful, and the washing area must be in an area where exposures are below permissible limits and published exposure levels.",
      "employee_scope_text": "Employees at temporary hazardous-waste worksites covered by 29 CFR 1910.120(n).",
      "minimum_facility_text": "20 or fewer: 1; more than 20 but fewer than 200: 1 toilet seat and 1 urinal per 40 workers; more than 200: 1 toilet seat and 1 urinal per 50 workers.",
      "portable_facility_status": "Where no sanitary sewer is available, chemical, recirculating, combustion, or flush toilets are permitted unless prohibited by local codes.",
      "access_rule": "A mobile-crew exception applies when transportation is readily available to nearby toilet facilities.",
      "service_rule": "No fixed servicing interval is stated in paragraph (n).",
      "washing_rule": "Adequate washing facilities must be provided in near proximity where hazardous substances may be harmful, and the washing area must be in an area where exposures are below permissible limits and published exposure levels.",
      "privacy_lock_rule": "Doors entering toilet facilities must have entrance locks controlled from inside the facility.",
      "sex_separation_rule": "No sex-separation provision is stated in paragraph (n).",
      "exception_text": "Mobile crews with readily available transportation to nearby toilet facilities are excepted.",
      "source_agency": "U.S. Occupational Safety and Health Administration",
      "source_title": "29 CFR 1910.120 — Hazardous Waste Operations and Emergency Response",
      "source_url": "https://www.osha.gov/laws-regs/regulations/standardnumber/1910/1910.120",
      "source_document_date": "",
      "verification_date": "2026-07-27",
      "verification_tier": "★",
      "source_text_note": "Exactly 200 employees is not assigned to a printed row because the middle row is fewer than 200 and the final row is more than 200."
    },
    {
      "record_id": "hazwoper-general-07",
      "dataset_version": "1.0.0",
      "jurisdiction_level": "Federal",
      "jurisdiction_name": "United States",
      "workplace_category": "HAZWOPER — general industry",
      "standard_number": "29 CFR 1910.120(n)",
      "requirement_type": "privacy_lock",
      "requirement_text": "Doors entering toilet facilities must have entrance locks controlled from inside the facility.",
      "employee_scope_text": "Employees at temporary hazardous-waste worksites covered by 29 CFR 1910.120(n).",
      "minimum_facility_text": "20 or fewer: 1; more than 20 but fewer than 200: 1 toilet seat and 1 urinal per 40 workers; more than 200: 1 toilet seat and 1 urinal per 50 workers.",
      "portable_facility_status": "Where no sanitary sewer is available, chemical, recirculating, combustion, or flush toilets are permitted unless prohibited by local codes.",
      "access_rule": "A mobile-crew exception applies when transportation is readily available to nearby toilet facilities.",
      "service_rule": "No fixed servicing interval is stated in paragraph (n).",
      "washing_rule": "Adequate washing facilities must be provided in near proximity where hazardous substances may be harmful, and the washing area must be in an area where exposures are below permissible limits and published exposure levels.",
      "privacy_lock_rule": "Doors entering toilet facilities must have entrance locks controlled from inside the facility.",
      "sex_separation_rule": "No sex-separation provision is stated in paragraph (n).",
      "exception_text": "Mobile crews with readily available transportation to nearby toilet facilities are excepted.",
      "source_agency": "U.S. Occupational Safety and Health Administration",
      "source_title": "29 CFR 1910.120 — Hazardous Waste Operations and Emergency Response",
      "source_url": "https://www.osha.gov/laws-regs/regulations/standardnumber/1910/1910.120",
      "source_document_date": "",
      "verification_date": "2026-07-27",
      "verification_tier": "★",
      "source_text_note": "Exactly 200 employees is not assigned to a printed row because the middle row is fewer than 200 and the final row is more than 200."
    },
    {
      "record_id": "hazwoper-general-08",
      "dataset_version": "1.0.0",
      "jurisdiction_level": "Federal",
      "jurisdiction_name": "United States",
      "workplace_category": "HAZWOPER — general industry",
      "standard_number": "29 CFR 1910.120(n)",
      "requirement_type": "sex_separation",
      "requirement_text": "No sex-separation provision is stated in paragraph (n).",
      "employee_scope_text": "Employees at temporary hazardous-waste worksites covered by 29 CFR 1910.120(n).",
      "minimum_facility_text": "20 or fewer: 1; more than 20 but fewer than 200: 1 toilet seat and 1 urinal per 40 workers; more than 200: 1 toilet seat and 1 urinal per 50 workers.",
      "portable_facility_status": "Where no sanitary sewer is available, chemical, recirculating, combustion, or flush toilets are permitted unless prohibited by local codes.",
      "access_rule": "A mobile-crew exception applies when transportation is readily available to nearby toilet facilities.",
      "service_rule": "No fixed servicing interval is stated in paragraph (n).",
      "washing_rule": "Adequate washing facilities must be provided in near proximity where hazardous substances may be harmful, and the washing area must be in an area where exposures are below permissible limits and published exposure levels.",
      "privacy_lock_rule": "Doors entering toilet facilities must have entrance locks controlled from inside the facility.",
      "sex_separation_rule": "No sex-separation provision is stated in paragraph (n).",
      "exception_text": "Mobile crews with readily available transportation to nearby toilet facilities are excepted.",
      "source_agency": "U.S. Occupational Safety and Health Administration",
      "source_title": "29 CFR 1910.120 — Hazardous Waste Operations and Emergency Response",
      "source_url": "https://www.osha.gov/laws-regs/regulations/standardnumber/1910/1910.120",
      "source_document_date": "",
      "verification_date": "2026-07-27",
      "verification_tier": "★",
      "source_text_note": "Exactly 200 employees is not assigned to a printed row because the middle row is fewer than 200 and the final row is more than 200."
    },
    {
      "record_id": "hazwoper-general-09",
      "dataset_version": "1.0.0",
      "jurisdiction_level": "Federal",
      "jurisdiction_name": "United States",
      "workplace_category": "HAZWOPER — general industry",
      "standard_number": "29 CFR 1910.120(n)",
      "requirement_type": "exceptions",
      "requirement_text": "Mobile crews with readily available transportation to nearby toilet facilities are excepted.",
      "employee_scope_text": "Employees at temporary hazardous-waste worksites covered by 29 CFR 1910.120(n).",
      "minimum_facility_text": "20 or fewer: 1; more than 20 but fewer than 200: 1 toilet seat and 1 urinal per 40 workers; more than 200: 1 toilet seat and 1 urinal per 50 workers.",
      "portable_facility_status": "Where no sanitary sewer is available, chemical, recirculating, combustion, or flush toilets are permitted unless prohibited by local codes.",
      "access_rule": "A mobile-crew exception applies when transportation is readily available to nearby toilet facilities.",
      "service_rule": "No fixed servicing interval is stated in paragraph (n).",
      "washing_rule": "Adequate washing facilities must be provided in near proximity where hazardous substances may be harmful, and the washing area must be in an area where exposures are below permissible limits and published exposure levels.",
      "privacy_lock_rule": "Doors entering toilet facilities must have entrance locks controlled from inside the facility.",
      "sex_separation_rule": "No sex-separation provision is stated in paragraph (n).",
      "exception_text": "Mobile crews with readily available transportation to nearby toilet facilities are excepted.",
      "source_agency": "U.S. Occupational Safety and Health Administration",
      "source_title": "29 CFR 1910.120 — Hazardous Waste Operations and Emergency Response",
      "source_url": "https://www.osha.gov/laws-regs/regulations/standardnumber/1910/1910.120",
      "source_document_date": "",
      "verification_date": "2026-07-27",
      "verification_tier": "★",
      "source_text_note": "Exactly 200 employees is not assigned to a printed row because the middle row is fewer than 200 and the final row is more than 200."
    },
    {
      "record_id": "hazwoper-construction-01",
      "dataset_version": "1.0.0",
      "jurisdiction_level": "Federal",
      "jurisdiction_name": "United States",
      "workplace_category": "HAZWOPER — construction",
      "standard_number": "29 CFR 1926.65(n)",
      "requirement_type": "employee_count",
      "requirement_text": "20 or fewer: 1; more than 20 but fewer than 200: 1 toilet seat and 1 urinal per 40 workers; more than 200: 1 toilet seat and 1 urinal per 50 workers.",
      "employee_scope_text": "Employees at temporary hazardous-waste worksites covered by 29 CFR 1926.65(n).",
      "minimum_facility_text": "20 or fewer: 1; more than 20 but fewer than 200: 1 toilet seat and 1 urinal per 40 workers; more than 200: 1 toilet seat and 1 urinal per 50 workers.",
      "portable_facility_status": "Where no sanitary sewer is available, chemical, recirculating, combustion, or flush toilets are permitted unless prohibited by local codes.",
      "access_rule": "A mobile-crew exception applies when transportation is readily available to nearby toilet facilities.",
      "service_rule": "No fixed servicing interval is stated in paragraph (n).",
      "washing_rule": "Adequate washing facilities must be provided in near proximity where hazardous substances may be harmful, and the washing area must be in an area where exposures are below permissible limits and published exposure levels.",
      "privacy_lock_rule": "Doors entering toilet facilities must have entrance locks controlled from inside the facility.",
      "sex_separation_rule": "No sex-separation provision is stated in paragraph (n).",
      "exception_text": "Mobile crews with readily available transportation to nearby toilet facilities are excepted.",
      "source_agency": "U.S. Occupational Safety and Health Administration",
      "source_title": "29 CFR 1926.65 — Hazardous Waste Operations and Emergency Response",
      "source_url": "https://www.osha.gov/laws-regs/regulations/standardnumber/1926/1926.65",
      "source_document_date": "",
      "verification_date": "2026-07-27",
      "verification_tier": "★",
      "source_text_note": "Exactly 200 employees is not assigned to a printed row because the middle row is fewer than 200 and the final row is more than 200."
    },
    {
      "record_id": "hazwoper-construction-02",
      "dataset_version": "1.0.0",
      "jurisdiction_level": "Federal",
      "jurisdiction_name": "United States",
      "workplace_category": "HAZWOPER — construction",
      "standard_number": "29 CFR 1926.65(n)",
      "requirement_type": "denominator",
      "requirement_text": "Employees at temporary hazardous-waste worksites covered by 29 CFR 1926.65(n).",
      "employee_scope_text": "Employees at temporary hazardous-waste worksites covered by 29 CFR 1926.65(n).",
      "minimum_facility_text": "20 or fewer: 1; more than 20 but fewer than 200: 1 toilet seat and 1 urinal per 40 workers; more than 200: 1 toilet seat and 1 urinal per 50 workers.",
      "portable_facility_status": "Where no sanitary sewer is available, chemical, recirculating, combustion, or flush toilets are permitted unless prohibited by local codes.",
      "access_rule": "A mobile-crew exception applies when transportation is readily available to nearby toilet facilities.",
      "service_rule": "No fixed servicing interval is stated in paragraph (n).",
      "washing_rule": "Adequate washing facilities must be provided in near proximity where hazardous substances may be harmful, and the washing area must be in an area where exposures are below permissible limits and published exposure levels.",
      "privacy_lock_rule": "Doors entering toilet facilities must have entrance locks controlled from inside the facility.",
      "sex_separation_rule": "No sex-separation provision is stated in paragraph (n).",
      "exception_text": "Mobile crews with readily available transportation to nearby toilet facilities are excepted.",
      "source_agency": "U.S. Occupational Safety and Health Administration",
      "source_title": "29 CFR 1926.65 — Hazardous Waste Operations and Emergency Response",
      "source_url": "https://www.osha.gov/laws-regs/regulations/standardnumber/1926/1926.65",
      "source_document_date": "",
      "verification_date": "2026-07-27",
      "verification_tier": "★",
      "source_text_note": "Exactly 200 employees is not assigned to a printed row because the middle row is fewer than 200 and the final row is more than 200."
    },
    {
      "record_id": "hazwoper-construction-03",
      "dataset_version": "1.0.0",
      "jurisdiction_level": "Federal",
      "jurisdiction_name": "United States",
      "workplace_category": "HAZWOPER — construction",
      "standard_number": "29 CFR 1926.65(n)",
      "requirement_type": "portable_units",
      "requirement_text": "Where no sanitary sewer is available, chemical, recirculating, combustion, or flush toilets are permitted unless prohibited by local codes.",
      "employee_scope_text": "Employees at temporary hazardous-waste worksites covered by 29 CFR 1926.65(n).",
      "minimum_facility_text": "20 or fewer: 1; more than 20 but fewer than 200: 1 toilet seat and 1 urinal per 40 workers; more than 200: 1 toilet seat and 1 urinal per 50 workers.",
      "portable_facility_status": "Where no sanitary sewer is available, chemical, recirculating, combustion, or flush toilets are permitted unless prohibited by local codes.",
      "access_rule": "A mobile-crew exception applies when transportation is readily available to nearby toilet facilities.",
      "service_rule": "No fixed servicing interval is stated in paragraph (n).",
      "washing_rule": "Adequate washing facilities must be provided in near proximity where hazardous substances may be harmful, and the washing area must be in an area where exposures are below permissible limits and published exposure levels.",
      "privacy_lock_rule": "Doors entering toilet facilities must have entrance locks controlled from inside the facility.",
      "sex_separation_rule": "No sex-separation provision is stated in paragraph (n).",
      "exception_text": "Mobile crews with readily available transportation to nearby toilet facilities are excepted.",
      "source_agency": "U.S. Occupational Safety and Health Administration",
      "source_title": "29 CFR 1926.65 — Hazardous Waste Operations and Emergency Response",
      "source_url": "https://www.osha.gov/laws-regs/regulations/standardnumber/1926/1926.65",
      "source_document_date": "",
      "verification_date": "2026-07-27",
      "verification_tier": "★",
      "source_text_note": "Exactly 200 employees is not assigned to a printed row because the middle row is fewer than 200 and the final row is more than 200."
    },
    {
      "record_id": "hazwoper-construction-04",
      "dataset_version": "1.0.0",
      "jurisdiction_level": "Federal",
      "jurisdiction_name": "United States",
      "workplace_category": "HAZWOPER — construction",
      "standard_number": "29 CFR 1926.65(n)",
      "requirement_type": "access",
      "requirement_text": "A mobile-crew exception applies when transportation is readily available to nearby toilet facilities.",
      "employee_scope_text": "Employees at temporary hazardous-waste worksites covered by 29 CFR 1926.65(n).",
      "minimum_facility_text": "20 or fewer: 1; more than 20 but fewer than 200: 1 toilet seat and 1 urinal per 40 workers; more than 200: 1 toilet seat and 1 urinal per 50 workers.",
      "portable_facility_status": "Where no sanitary sewer is available, chemical, recirculating, combustion, or flush toilets are permitted unless prohibited by local codes.",
      "access_rule": "A mobile-crew exception applies when transportation is readily available to nearby toilet facilities.",
      "service_rule": "No fixed servicing interval is stated in paragraph (n).",
      "washing_rule": "Adequate washing facilities must be provided in near proximity where hazardous substances may be harmful, and the washing area must be in an area where exposures are below permissible limits and published exposure levels.",
      "privacy_lock_rule": "Doors entering toilet facilities must have entrance locks controlled from inside the facility.",
      "sex_separation_rule": "No sex-separation provision is stated in paragraph (n).",
      "exception_text": "Mobile crews with readily available transportation to nearby toilet facilities are excepted.",
      "source_agency": "U.S. Occupational Safety and Health Administration",
      "source_title": "29 CFR 1926.65 — Hazardous Waste Operations and Emergency Response",
      "source_url": "https://www.osha.gov/laws-regs/regulations/standardnumber/1926/1926.65",
      "source_document_date": "",
      "verification_date": "2026-07-27",
      "verification_tier": "★",
      "source_text_note": "Exactly 200 employees is not assigned to a printed row because the middle row is fewer than 200 and the final row is more than 200."
    },
    {
      "record_id": "hazwoper-construction-05",
      "dataset_version": "1.0.0",
      "jurisdiction_level": "Federal",
      "jurisdiction_name": "United States",
      "workplace_category": "HAZWOPER — construction",
      "standard_number": "29 CFR 1926.65(n)",
      "requirement_type": "servicing",
      "requirement_text": "No fixed servicing interval is stated in paragraph (n).",
      "employee_scope_text": "Employees at temporary hazardous-waste worksites covered by 29 CFR 1926.65(n).",
      "minimum_facility_text": "20 or fewer: 1; more than 20 but fewer than 200: 1 toilet seat and 1 urinal per 40 workers; more than 200: 1 toilet seat and 1 urinal per 50 workers.",
      "portable_facility_status": "Where no sanitary sewer is available, chemical, recirculating, combustion, or flush toilets are permitted unless prohibited by local codes.",
      "access_rule": "A mobile-crew exception applies when transportation is readily available to nearby toilet facilities.",
      "service_rule": "No fixed servicing interval is stated in paragraph (n).",
      "washing_rule": "Adequate washing facilities must be provided in near proximity where hazardous substances may be harmful, and the washing area must be in an area where exposures are below permissible limits and published exposure levels.",
      "privacy_lock_rule": "Doors entering toilet facilities must have entrance locks controlled from inside the facility.",
      "sex_separation_rule": "No sex-separation provision is stated in paragraph (n).",
      "exception_text": "Mobile crews with readily available transportation to nearby toilet facilities are excepted.",
      "source_agency": "U.S. Occupational Safety and Health Administration",
      "source_title": "29 CFR 1926.65 — Hazardous Waste Operations and Emergency Response",
      "source_url": "https://www.osha.gov/laws-regs/regulations/standardnumber/1926/1926.65",
      "source_document_date": "",
      "verification_date": "2026-07-27",
      "verification_tier": "★",
      "source_text_note": "Exactly 200 employees is not assigned to a printed row because the middle row is fewer than 200 and the final row is more than 200."
    },
    {
      "record_id": "hazwoper-construction-06",
      "dataset_version": "1.0.0",
      "jurisdiction_level": "Federal",
      "jurisdiction_name": "United States",
      "workplace_category": "HAZWOPER — construction",
      "standard_number": "29 CFR 1926.65(n)",
      "requirement_type": "washing",
      "requirement_text": "Adequate washing facilities must be provided in near proximity where hazardous substances may be harmful, and the washing area must be in an area where exposures are below permissible limits and published exposure levels.",
      "employee_scope_text": "Employees at temporary hazardous-waste worksites covered by 29 CFR 1926.65(n).",
      "minimum_facility_text": "20 or fewer: 1; more than 20 but fewer than 200: 1 toilet seat and 1 urinal per 40 workers; more than 200: 1 toilet seat and 1 urinal per 50 workers.",
      "portable_facility_status": "Where no sanitary sewer is available, chemical, recirculating, combustion, or flush toilets are permitted unless prohibited by local codes.",
      "access_rule": "A mobile-crew exception applies when transportation is readily available to nearby toilet facilities.",
      "service_rule": "No fixed servicing interval is stated in paragraph (n).",
      "washing_rule": "Adequate washing facilities must be provided in near proximity where hazardous substances may be harmful, and the washing area must be in an area where exposures are below permissible limits and published exposure levels.",
      "privacy_lock_rule": "Doors entering toilet facilities must have entrance locks controlled from inside the facility.",
      "sex_separation_rule": "No sex-separation provision is stated in paragraph (n).",
      "exception_text": "Mobile crews with readily available transportation to nearby toilet facilities are excepted.",
      "source_agency": "U.S. Occupational Safety and Health Administration",
      "source_title": "29 CFR 1926.65 — Hazardous Waste Operations and Emergency Response",
      "source_url": "https://www.osha.gov/laws-regs/regulations/standardnumber/1926/1926.65",
      "source_document_date": "",
      "verification_date": "2026-07-27",
      "verification_tier": "★",
      "source_text_note": "Exactly 200 employees is not assigned to a printed row because the middle row is fewer than 200 and the final row is more than 200."
    },
    {
      "record_id": "hazwoper-construction-07",
      "dataset_version": "1.0.0",
      "jurisdiction_level": "Federal",
      "jurisdiction_name": "United States",
      "workplace_category": "HAZWOPER — construction",
      "standard_number": "29 CFR 1926.65(n)",
      "requirement_type": "privacy_lock",
      "requirement_text": "Doors entering toilet facilities must have entrance locks controlled from inside the facility.",
      "employee_scope_text": "Employees at temporary hazardous-waste worksites covered by 29 CFR 1926.65(n).",
      "minimum_facility_text": "20 or fewer: 1; more than 20 but fewer than 200: 1 toilet seat and 1 urinal per 40 workers; more than 200: 1 toilet seat and 1 urinal per 50 workers.",
      "portable_facility_status": "Where no sanitary sewer is available, chemical, recirculating, combustion, or flush toilets are permitted unless prohibited by local codes.",
      "access_rule": "A mobile-crew exception applies when transportation is readily available to nearby toilet facilities.",
      "service_rule": "No fixed servicing interval is stated in paragraph (n).",
      "washing_rule": "Adequate washing facilities must be provided in near proximity where hazardous substances may be harmful, and the washing area must be in an area where exposures are below permissible limits and published exposure levels.",
      "privacy_lock_rule": "Doors entering toilet facilities must have entrance locks controlled from inside the facility.",
      "sex_separation_rule": "No sex-separation provision is stated in paragraph (n).",
      "exception_text": "Mobile crews with readily available transportation to nearby toilet facilities are excepted.",
      "source_agency": "U.S. Occupational Safety and Health Administration",
      "source_title": "29 CFR 1926.65 — Hazardous Waste Operations and Emergency Response",
      "source_url": "https://www.osha.gov/laws-regs/regulations/standardnumber/1926/1926.65",
      "source_document_date": "",
      "verification_date": "2026-07-27",
      "verification_tier": "★",
      "source_text_note": "Exactly 200 employees is not assigned to a printed row because the middle row is fewer than 200 and the final row is more than 200."
    },
    {
      "record_id": "hazwoper-construction-08",
      "dataset_version": "1.0.0",
      "jurisdiction_level": "Federal",
      "jurisdiction_name": "United States",
      "workplace_category": "HAZWOPER — construction",
      "standard_number": "29 CFR 1926.65(n)",
      "requirement_type": "sex_separation",
      "requirement_text": "No sex-separation provision is stated in paragraph (n).",
      "employee_scope_text": "Employees at temporary hazardous-waste worksites covered by 29 CFR 1926.65(n).",
      "minimum_facility_text": "20 or fewer: 1; more than 20 but fewer than 200: 1 toilet seat and 1 urinal per 40 workers; more than 200: 1 toilet seat and 1 urinal per 50 workers.",
      "portable_facility_status": "Where no sanitary sewer is available, chemical, recirculating, combustion, or flush toilets are permitted unless prohibited by local codes.",
      "access_rule": "A mobile-crew exception applies when transportation is readily available to nearby toilet facilities.",
      "service_rule": "No fixed servicing interval is stated in paragraph (n).",
      "washing_rule": "Adequate washing facilities must be provided in near proximity where hazardous substances may be harmful, and the washing area must be in an area where exposures are below permissible limits and published exposure levels.",
      "privacy_lock_rule": "Doors entering toilet facilities must have entrance locks controlled from inside the facility.",
      "sex_separation_rule": "No sex-separation provision is stated in paragraph (n).",
      "exception_text": "Mobile crews with readily available transportation to nearby toilet facilities are excepted.",
      "source_agency": "U.S. Occupational Safety and Health Administration",
      "source_title": "29 CFR 1926.65 — Hazardous Waste Operations and Emergency Response",
      "source_url": "https://www.osha.gov/laws-regs/regulations/standardnumber/1926/1926.65",
      "source_document_date": "",
      "verification_date": "2026-07-27",
      "verification_tier": "★",
      "source_text_note": "Exactly 200 employees is not assigned to a printed row because the middle row is fewer than 200 and the final row is more than 200."
    },
    {
      "record_id": "hazwoper-construction-09",
      "dataset_version": "1.0.0",
      "jurisdiction_level": "Federal",
      "jurisdiction_name": "United States",
      "workplace_category": "HAZWOPER — construction",
      "standard_number": "29 CFR 1926.65(n)",
      "requirement_type": "exceptions",
      "requirement_text": "Mobile crews with readily available transportation to nearby toilet facilities are excepted.",
      "employee_scope_text": "Employees at temporary hazardous-waste worksites covered by 29 CFR 1926.65(n).",
      "minimum_facility_text": "20 or fewer: 1; more than 20 but fewer than 200: 1 toilet seat and 1 urinal per 40 workers; more than 200: 1 toilet seat and 1 urinal per 50 workers.",
      "portable_facility_status": "Where no sanitary sewer is available, chemical, recirculating, combustion, or flush toilets are permitted unless prohibited by local codes.",
      "access_rule": "A mobile-crew exception applies when transportation is readily available to nearby toilet facilities.",
      "service_rule": "No fixed servicing interval is stated in paragraph (n).",
      "washing_rule": "Adequate washing facilities must be provided in near proximity where hazardous substances may be harmful, and the washing area must be in an area where exposures are below permissible limits and published exposure levels.",
      "privacy_lock_rule": "Doors entering toilet facilities must have entrance locks controlled from inside the facility.",
      "sex_separation_rule": "No sex-separation provision is stated in paragraph (n).",
      "exception_text": "Mobile crews with readily available transportation to nearby toilet facilities are excepted.",
      "source_agency": "U.S. Occupational Safety and Health Administration",
      "source_title": "29 CFR 1926.65 — Hazardous Waste Operations and Emergency Response",
      "source_url": "https://www.osha.gov/laws-regs/regulations/standardnumber/1926/1926.65",
      "source_document_date": "",
      "verification_date": "2026-07-27",
      "verification_tier": "★",
      "source_text_note": "Exactly 200 employees is not assigned to a printed row because the middle row is fewer than 200 and the final row is more than 200."
    },
    {
      "record_id": "marine-terminals-01",
      "dataset_version": "1.0.0",
      "jurisdiction_level": "Federal",
      "jurisdiction_name": "United States",
      "workplace_category": "Marine terminals",
      "standard_number": "29 CFR 1917.127",
      "requirement_type": "employee_count",
      "requirement_text": "No employee-count table. Fixed or portable toilets must be sufficient for employees’ sanitary requirements.",
      "employee_scope_text": "Employees performing covered marine-terminal work.",
      "minimum_facility_text": "No employee-count table. Fixed or portable toilets must be sufficient for employees’ sanitary requirements.",
      "portable_facility_status": "Fixed or portable toilets are expressly allowed.",
      "access_rule": "The employer must provide accessible washing and toilet facilities sufficient for employees’ sanitary requirements.",
      "service_rule": "Toilets must be regularly cleaned and maintained in good order.",
      "washing_rule": "Running water—hot and cold or tepid—must be available at a minimum of one accessible location. Potable water may substitute where permanent facilities are not available. Soap and drying means are required.",
      "privacy_lock_rule": "Separate compartments must have latch-equipped doors.",
      "sex_separation_rule": "Separate facilities are required for each sex unless the toilet room will be occupied by only one person at a time.",
      "exception_text": "The standard provides a potable-water substitution where permanent washing facilities are not available.",
      "source_agency": "U.S. Occupational Safety and Health Administration",
      "source_title": "29 CFR 1917.127 — Sanitation",
      "source_url": "https://www.osha.gov/laws-regs/regulations/standardnumber/1917/1917.127",
      "source_document_date": "",
      "verification_date": "2026-07-27",
      "verification_tier": "★",
      "source_text_note": "The standard uses a sufficiency requirement rather than an employee-count table."
    },
    {
      "record_id": "marine-terminals-02",
      "dataset_version": "1.0.0",
      "jurisdiction_level": "Federal",
      "jurisdiction_name": "United States",
      "workplace_category": "Marine terminals",
      "standard_number": "29 CFR 1917.127",
      "requirement_type": "denominator",
      "requirement_text": "Employees performing covered marine-terminal work.",
      "employee_scope_text": "Employees performing covered marine-terminal work.",
      "minimum_facility_text": "No employee-count table. Fixed or portable toilets must be sufficient for employees’ sanitary requirements.",
      "portable_facility_status": "Fixed or portable toilets are expressly allowed.",
      "access_rule": "The employer must provide accessible washing and toilet facilities sufficient for employees’ sanitary requirements.",
      "service_rule": "Toilets must be regularly cleaned and maintained in good order.",
      "washing_rule": "Running water—hot and cold or tepid—must be available at a minimum of one accessible location. Potable water may substitute where permanent facilities are not available. Soap and drying means are required.",
      "privacy_lock_rule": "Separate compartments must have latch-equipped doors.",
      "sex_separation_rule": "Separate facilities are required for each sex unless the toilet room will be occupied by only one person at a time.",
      "exception_text": "The standard provides a potable-water substitution where permanent washing facilities are not available.",
      "source_agency": "U.S. Occupational Safety and Health Administration",
      "source_title": "29 CFR 1917.127 — Sanitation",
      "source_url": "https://www.osha.gov/laws-regs/regulations/standardnumber/1917/1917.127",
      "source_document_date": "",
      "verification_date": "2026-07-27",
      "verification_tier": "★",
      "source_text_note": "The standard uses a sufficiency requirement rather than an employee-count table."
    },
    {
      "record_id": "marine-terminals-03",
      "dataset_version": "1.0.0",
      "jurisdiction_level": "Federal",
      "jurisdiction_name": "United States",
      "workplace_category": "Marine terminals",
      "standard_number": "29 CFR 1917.127",
      "requirement_type": "portable_units",
      "requirement_text": "Fixed or portable toilets are expressly allowed.",
      "employee_scope_text": "Employees performing covered marine-terminal work.",
      "minimum_facility_text": "No employee-count table. Fixed or portable toilets must be sufficient for employees’ sanitary requirements.",
      "portable_facility_status": "Fixed or portable toilets are expressly allowed.",
      "access_rule": "The employer must provide accessible washing and toilet facilities sufficient for employees’ sanitary requirements.",
      "service_rule": "Toilets must be regularly cleaned and maintained in good order.",
      "washing_rule": "Running water—hot and cold or tepid—must be available at a minimum of one accessible location. Potable water may substitute where permanent facilities are not available. Soap and drying means are required.",
      "privacy_lock_rule": "Separate compartments must have latch-equipped doors.",
      "sex_separation_rule": "Separate facilities are required for each sex unless the toilet room will be occupied by only one person at a time.",
      "exception_text": "The standard provides a potable-water substitution where permanent washing facilities are not available.",
      "source_agency": "U.S. Occupational Safety and Health Administration",
      "source_title": "29 CFR 1917.127 — Sanitation",
      "source_url": "https://www.osha.gov/laws-regs/regulations/standardnumber/1917/1917.127",
      "source_document_date": "",
      "verification_date": "2026-07-27",
      "verification_tier": "★",
      "source_text_note": "The standard uses a sufficiency requirement rather than an employee-count table."
    },
    {
      "record_id": "marine-terminals-04",
      "dataset_version": "1.0.0",
      "jurisdiction_level": "Federal",
      "jurisdiction_name": "United States",
      "workplace_category": "Marine terminals",
      "standard_number": "29 CFR 1917.127",
      "requirement_type": "access",
      "requirement_text": "The employer must provide accessible washing and toilet facilities sufficient for employees’ sanitary requirements.",
      "employee_scope_text": "Employees performing covered marine-terminal work.",
      "minimum_facility_text": "No employee-count table. Fixed or portable toilets must be sufficient for employees’ sanitary requirements.",
      "portable_facility_status": "Fixed or portable toilets are expressly allowed.",
      "access_rule": "The employer must provide accessible washing and toilet facilities sufficient for employees’ sanitary requirements.",
      "service_rule": "Toilets must be regularly cleaned and maintained in good order.",
      "washing_rule": "Running water—hot and cold or tepid—must be available at a minimum of one accessible location. Potable water may substitute where permanent facilities are not available. Soap and drying means are required.",
      "privacy_lock_rule": "Separate compartments must have latch-equipped doors.",
      "sex_separation_rule": "Separate facilities are required for each sex unless the toilet room will be occupied by only one person at a time.",
      "exception_text": "The standard provides a potable-water substitution where permanent washing facilities are not available.",
      "source_agency": "U.S. Occupational Safety and Health Administration",
      "source_title": "29 CFR 1917.127 — Sanitation",
      "source_url": "https://www.osha.gov/laws-regs/regulations/standardnumber/1917/1917.127",
      "source_document_date": "",
      "verification_date": "2026-07-27",
      "verification_tier": "★",
      "source_text_note": "The standard uses a sufficiency requirement rather than an employee-count table."
    },
    {
      "record_id": "marine-terminals-05",
      "dataset_version": "1.0.0",
      "jurisdiction_level": "Federal",
      "jurisdiction_name": "United States",
      "workplace_category": "Marine terminals",
      "standard_number": "29 CFR 1917.127",
      "requirement_type": "servicing",
      "requirement_text": "Toilets must be regularly cleaned and maintained in good order.",
      "employee_scope_text": "Employees performing covered marine-terminal work.",
      "minimum_facility_text": "No employee-count table. Fixed or portable toilets must be sufficient for employees’ sanitary requirements.",
      "portable_facility_status": "Fixed or portable toilets are expressly allowed.",
      "access_rule": "The employer must provide accessible washing and toilet facilities sufficient for employees’ sanitary requirements.",
      "service_rule": "Toilets must be regularly cleaned and maintained in good order.",
      "washing_rule": "Running water—hot and cold or tepid—must be available at a minimum of one accessible location. Potable water may substitute where permanent facilities are not available. Soap and drying means are required.",
      "privacy_lock_rule": "Separate compartments must have latch-equipped doors.",
      "sex_separation_rule": "Separate facilities are required for each sex unless the toilet room will be occupied by only one person at a time.",
      "exception_text": "The standard provides a potable-water substitution where permanent washing facilities are not available.",
      "source_agency": "U.S. Occupational Safety and Health Administration",
      "source_title": "29 CFR 1917.127 — Sanitation",
      "source_url": "https://www.osha.gov/laws-regs/regulations/standardnumber/1917/1917.127",
      "source_document_date": "",
      "verification_date": "2026-07-27",
      "verification_tier": "★",
      "source_text_note": "The standard uses a sufficiency requirement rather than an employee-count table."
    },
    {
      "record_id": "marine-terminals-06",
      "dataset_version": "1.0.0",
      "jurisdiction_level": "Federal",
      "jurisdiction_name": "United States",
      "workplace_category": "Marine terminals",
      "standard_number": "29 CFR 1917.127",
      "requirement_type": "washing",
      "requirement_text": "Running water—hot and cold or tepid—must be available at a minimum of one accessible location. Potable water may substitute where permanent facilities are not available. Soap and drying means are required.",
      "employee_scope_text": "Employees performing covered marine-terminal work.",
      "minimum_facility_text": "No employee-count table. Fixed or portable toilets must be sufficient for employees’ sanitary requirements.",
      "portable_facility_status": "Fixed or portable toilets are expressly allowed.",
      "access_rule": "The employer must provide accessible washing and toilet facilities sufficient for employees’ sanitary requirements.",
      "service_rule": "Toilets must be regularly cleaned and maintained in good order.",
      "washing_rule": "Running water—hot and cold or tepid—must be available at a minimum of one accessible location. Potable water may substitute where permanent facilities are not available. Soap and drying means are required.",
      "privacy_lock_rule": "Separate compartments must have latch-equipped doors.",
      "sex_separation_rule": "Separate facilities are required for each sex unless the toilet room will be occupied by only one person at a time.",
      "exception_text": "The standard provides a potable-water substitution where permanent washing facilities are not available.",
      "source_agency": "U.S. Occupational Safety and Health Administration",
      "source_title": "29 CFR 1917.127 — Sanitation",
      "source_url": "https://www.osha.gov/laws-regs/regulations/standardnumber/1917/1917.127",
      "source_document_date": "",
      "verification_date": "2026-07-27",
      "verification_tier": "★",
      "source_text_note": "The standard uses a sufficiency requirement rather than an employee-count table."
    },
    {
      "record_id": "marine-terminals-07",
      "dataset_version": "1.0.0",
      "jurisdiction_level": "Federal",
      "jurisdiction_name": "United States",
      "workplace_category": "Marine terminals",
      "standard_number": "29 CFR 1917.127",
      "requirement_type": "privacy_lock",
      "requirement_text": "Separate compartments must have latch-equipped doors.",
      "employee_scope_text": "Employees performing covered marine-terminal work.",
      "minimum_facility_text": "No employee-count table. Fixed or portable toilets must be sufficient for employees’ sanitary requirements.",
      "portable_facility_status": "Fixed or portable toilets are expressly allowed.",
      "access_rule": "The employer must provide accessible washing and toilet facilities sufficient for employees’ sanitary requirements.",
      "service_rule": "Toilets must be regularly cleaned and maintained in good order.",
      "washing_rule": "Running water—hot and cold or tepid—must be available at a minimum of one accessible location. Potable water may substitute where permanent facilities are not available. Soap and drying means are required.",
      "privacy_lock_rule": "Separate compartments must have latch-equipped doors.",
      "sex_separation_rule": "Separate facilities are required for each sex unless the toilet room will be occupied by only one person at a time.",
      "exception_text": "The standard provides a potable-water substitution where permanent washing facilities are not available.",
      "source_agency": "U.S. Occupational Safety and Health Administration",
      "source_title": "29 CFR 1917.127 — Sanitation",
      "source_url": "https://www.osha.gov/laws-regs/regulations/standardnumber/1917/1917.127",
      "source_document_date": "",
      "verification_date": "2026-07-27",
      "verification_tier": "★",
      "source_text_note": "The standard uses a sufficiency requirement rather than an employee-count table."
    },
    {
      "record_id": "marine-terminals-08",
      "dataset_version": "1.0.0",
      "jurisdiction_level": "Federal",
      "jurisdiction_name": "United States",
      "workplace_category": "Marine terminals",
      "standard_number": "29 CFR 1917.127",
      "requirement_type": "sex_separation",
      "requirement_text": "Separate facilities are required for each sex unless the toilet room will be occupied by only one person at a time.",
      "employee_scope_text": "Employees performing covered marine-terminal work.",
      "minimum_facility_text": "No employee-count table. Fixed or portable toilets must be sufficient for employees’ sanitary requirements.",
      "portable_facility_status": "Fixed or portable toilets are expressly allowed.",
      "access_rule": "The employer must provide accessible washing and toilet facilities sufficient for employees’ sanitary requirements.",
      "service_rule": "Toilets must be regularly cleaned and maintained in good order.",
      "washing_rule": "Running water—hot and cold or tepid—must be available at a minimum of one accessible location. Potable water may substitute where permanent facilities are not available. Soap and drying means are required.",
      "privacy_lock_rule": "Separate compartments must have latch-equipped doors.",
      "sex_separation_rule": "Separate facilities are required for each sex unless the toilet room will be occupied by only one person at a time.",
      "exception_text": "The standard provides a potable-water substitution where permanent washing facilities are not available.",
      "source_agency": "U.S. Occupational Safety and Health Administration",
      "source_title": "29 CFR 1917.127 — Sanitation",
      "source_url": "https://www.osha.gov/laws-regs/regulations/standardnumber/1917/1917.127",
      "source_document_date": "",
      "verification_date": "2026-07-27",
      "verification_tier": "★",
      "source_text_note": "The standard uses a sufficiency requirement rather than an employee-count table."
    },
    {
      "record_id": "marine-terminals-09",
      "dataset_version": "1.0.0",
      "jurisdiction_level": "Federal",
      "jurisdiction_name": "United States",
      "workplace_category": "Marine terminals",
      "standard_number": "29 CFR 1917.127",
      "requirement_type": "exceptions",
      "requirement_text": "The standard provides a potable-water substitution where permanent washing facilities are not available.",
      "employee_scope_text": "Employees performing covered marine-terminal work.",
      "minimum_facility_text": "No employee-count table. Fixed or portable toilets must be sufficient for employees’ sanitary requirements.",
      "portable_facility_status": "Fixed or portable toilets are expressly allowed.",
      "access_rule": "The employer must provide accessible washing and toilet facilities sufficient for employees’ sanitary requirements.",
      "service_rule": "Toilets must be regularly cleaned and maintained in good order.",
      "washing_rule": "Running water—hot and cold or tepid—must be available at a minimum of one accessible location. Potable water may substitute where permanent facilities are not available. Soap and drying means are required.",
      "privacy_lock_rule": "Separate compartments must have latch-equipped doors.",
      "sex_separation_rule": "Separate facilities are required for each sex unless the toilet room will be occupied by only one person at a time.",
      "exception_text": "The standard provides a potable-water substitution where permanent washing facilities are not available.",
      "source_agency": "U.S. Occupational Safety and Health Administration",
      "source_title": "29 CFR 1917.127 — Sanitation",
      "source_url": "https://www.osha.gov/laws-regs/regulations/standardnumber/1917/1917.127",
      "source_document_date": "",
      "verification_date": "2026-07-27",
      "verification_tier": "★",
      "source_text_note": "The standard uses a sufficiency requirement rather than an employee-count table."
    },
    {
      "record_id": "longshoring-01",
      "dataset_version": "1.0.0",
      "jurisdiction_level": "Federal",
      "jurisdiction_name": "United States",
      "workplace_category": "Longshoring",
      "standard_number": "29 CFR 1918.95",
      "requirement_type": "employee_count",
      "requirement_text": "No employee-count table. Fixed or portable toilets must be sufficient for employees’ sanitary requirements.",
      "employee_scope_text": "Employees performing covered longshoring work.",
      "minimum_facility_text": "No employee-count table. Fixed or portable toilets must be sufficient for employees’ sanitary requirements.",
      "portable_facility_status": "Fixed or portable toilets are expressly allowed.",
      "access_rule": "Toilet and washing facilities must be readily accessible at the worksite.",
      "service_rule": "Toilets must be regularly cleaned and maintained in good order.",
      "washing_rule": "Running water—hot and cold or tepid—must be available at a minimum of one accessible location. Potable water may substitute where permanent facilities are not available. Soap and drying means are required.",
      "privacy_lock_rule": "Separate compartments must have latch-equipped doors.",
      "sex_separation_rule": "Separate facilities are required for each sex unless the toilet room will be occupied by only one person at a time.",
      "exception_text": "The standard provides a potable-water substitution where permanent washing facilities are not available.",
      "source_agency": "U.S. Occupational Safety and Health Administration",
      "source_title": "29 CFR 1918.95 — Sanitation",
      "source_url": "https://www.osha.gov/laws-regs/regulations/standardnumber/1918/1918.95",
      "source_document_date": "",
      "verification_date": "2026-07-27",
      "verification_tier": "★",
      "source_text_note": "The standard uses a sufficiency requirement rather than an employee-count table."
    },
    {
      "record_id": "longshoring-02",
      "dataset_version": "1.0.0",
      "jurisdiction_level": "Federal",
      "jurisdiction_name": "United States",
      "workplace_category": "Longshoring",
      "standard_number": "29 CFR 1918.95",
      "requirement_type": "denominator",
      "requirement_text": "Employees performing covered longshoring work.",
      "employee_scope_text": "Employees performing covered longshoring work.",
      "minimum_facility_text": "No employee-count table. Fixed or portable toilets must be sufficient for employees’ sanitary requirements.",
      "portable_facility_status": "Fixed or portable toilets are expressly allowed.",
      "access_rule": "Toilet and washing facilities must be readily accessible at the worksite.",
      "service_rule": "Toilets must be regularly cleaned and maintained in good order.",
      "washing_rule": "Running water—hot and cold or tepid—must be available at a minimum of one accessible location. Potable water may substitute where permanent facilities are not available. Soap and drying means are required.",
      "privacy_lock_rule": "Separate compartments must have latch-equipped doors.",
      "sex_separation_rule": "Separate facilities are required for each sex unless the toilet room will be occupied by only one person at a time.",
      "exception_text": "The standard provides a potable-water substitution where permanent washing facilities are not available.",
      "source_agency": "U.S. Occupational Safety and Health Administration",
      "source_title": "29 CFR 1918.95 — Sanitation",
      "source_url": "https://www.osha.gov/laws-regs/regulations/standardnumber/1918/1918.95",
      "source_document_date": "",
      "verification_date": "2026-07-27",
      "verification_tier": "★",
      "source_text_note": "The standard uses a sufficiency requirement rather than an employee-count table."
    },
    {
      "record_id": "longshoring-03",
      "dataset_version": "1.0.0",
      "jurisdiction_level": "Federal",
      "jurisdiction_name": "United States",
      "workplace_category": "Longshoring",
      "standard_number": "29 CFR 1918.95",
      "requirement_type": "portable_units",
      "requirement_text": "Fixed or portable toilets are expressly allowed.",
      "employee_scope_text": "Employees performing covered longshoring work.",
      "minimum_facility_text": "No employee-count table. Fixed or portable toilets must be sufficient for employees’ sanitary requirements.",
      "portable_facility_status": "Fixed or portable toilets are expressly allowed.",
      "access_rule": "Toilet and washing facilities must be readily accessible at the worksite.",
      "service_rule": "Toilets must be regularly cleaned and maintained in good order.",
      "washing_rule": "Running water—hot and cold or tepid—must be available at a minimum of one accessible location. Potable water may substitute where permanent facilities are not available. Soap and drying means are required.",
      "privacy_lock_rule": "Separate compartments must have latch-equipped doors.",
      "sex_separation_rule": "Separate facilities are required for each sex unless the toilet room will be occupied by only one person at a time.",
      "exception_text": "The standard provides a potable-water substitution where permanent washing facilities are not available.",
      "source_agency": "U.S. Occupational Safety and Health Administration",
      "source_title": "29 CFR 1918.95 — Sanitation",
      "source_url": "https://www.osha.gov/laws-regs/regulations/standardnumber/1918/1918.95",
      "source_document_date": "",
      "verification_date": "2026-07-27",
      "verification_tier": "★",
      "source_text_note": "The standard uses a sufficiency requirement rather than an employee-count table."
    },
    {
      "record_id": "longshoring-04",
      "dataset_version": "1.0.0",
      "jurisdiction_level": "Federal",
      "jurisdiction_name": "United States",
      "workplace_category": "Longshoring",
      "standard_number": "29 CFR 1918.95",
      "requirement_type": "access",
      "requirement_text": "Toilet and washing facilities must be readily accessible at the worksite.",
      "employee_scope_text": "Employees performing covered longshoring work.",
      "minimum_facility_text": "No employee-count table. Fixed or portable toilets must be sufficient for employees’ sanitary requirements.",
      "portable_facility_status": "Fixed or portable toilets are expressly allowed.",
      "access_rule": "Toilet and washing facilities must be readily accessible at the worksite.",
      "service_rule": "Toilets must be regularly cleaned and maintained in good order.",
      "washing_rule": "Running water—hot and cold or tepid—must be available at a minimum of one accessible location. Potable water may substitute where permanent facilities are not available. Soap and drying means are required.",
      "privacy_lock_rule": "Separate compartments must have latch-equipped doors.",
      "sex_separation_rule": "Separate facilities are required for each sex unless the toilet room will be occupied by only one person at a time.",
      "exception_text": "The standard provides a potable-water substitution where permanent washing facilities are not available.",
      "source_agency": "U.S. Occupational Safety and Health Administration",
      "source_title": "29 CFR 1918.95 — Sanitation",
      "source_url": "https://www.osha.gov/laws-regs/regulations/standardnumber/1918/1918.95",
      "source_document_date": "",
      "verification_date": "2026-07-27",
      "verification_tier": "★",
      "source_text_note": "The standard uses a sufficiency requirement rather than an employee-count table."
    },
    {
      "record_id": "longshoring-05",
      "dataset_version": "1.0.0",
      "jurisdiction_level": "Federal",
      "jurisdiction_name": "United States",
      "workplace_category": "Longshoring",
      "standard_number": "29 CFR 1918.95",
      "requirement_type": "servicing",
      "requirement_text": "Toilets must be regularly cleaned and maintained in good order.",
      "employee_scope_text": "Employees performing covered longshoring work.",
      "minimum_facility_text": "No employee-count table. Fixed or portable toilets must be sufficient for employees’ sanitary requirements.",
      "portable_facility_status": "Fixed or portable toilets are expressly allowed.",
      "access_rule": "Toilet and washing facilities must be readily accessible at the worksite.",
      "service_rule": "Toilets must be regularly cleaned and maintained in good order.",
      "washing_rule": "Running water—hot and cold or tepid—must be available at a minimum of one accessible location. Potable water may substitute where permanent facilities are not available. Soap and drying means are required.",
      "privacy_lock_rule": "Separate compartments must have latch-equipped doors.",
      "sex_separation_rule": "Separate facilities are required for each sex unless the toilet room will be occupied by only one person at a time.",
      "exception_text": "The standard provides a potable-water substitution where permanent washing facilities are not available.",
      "source_agency": "U.S. Occupational Safety and Health Administration",
      "source_title": "29 CFR 1918.95 — Sanitation",
      "source_url": "https://www.osha.gov/laws-regs/regulations/standardnumber/1918/1918.95",
      "source_document_date": "",
      "verification_date": "2026-07-27",
      "verification_tier": "★",
      "source_text_note": "The standard uses a sufficiency requirement rather than an employee-count table."
    },
    {
      "record_id": "longshoring-06",
      "dataset_version": "1.0.0",
      "jurisdiction_level": "Federal",
      "jurisdiction_name": "United States",
      "workplace_category": "Longshoring",
      "standard_number": "29 CFR 1918.95",
      "requirement_type": "washing",
      "requirement_text": "Running water—hot and cold or tepid—must be available at a minimum of one accessible location. Potable water may substitute where permanent facilities are not available. Soap and drying means are required.",
      "employee_scope_text": "Employees performing covered longshoring work.",
      "minimum_facility_text": "No employee-count table. Fixed or portable toilets must be sufficient for employees’ sanitary requirements.",
      "portable_facility_status": "Fixed or portable toilets are expressly allowed.",
      "access_rule": "Toilet and washing facilities must be readily accessible at the worksite.",
      "service_rule": "Toilets must be regularly cleaned and maintained in good order.",
      "washing_rule": "Running water—hot and cold or tepid—must be available at a minimum of one accessible location. Potable water may substitute where permanent facilities are not available. Soap and drying means are required.",
      "privacy_lock_rule": "Separate compartments must have latch-equipped doors.",
      "sex_separation_rule": "Separate facilities are required for each sex unless the toilet room will be occupied by only one person at a time.",
      "exception_text": "The standard provides a potable-water substitution where permanent washing facilities are not available.",
      "source_agency": "U.S. Occupational Safety and Health Administration",
      "source_title": "29 CFR 1918.95 — Sanitation",
      "source_url": "https://www.osha.gov/laws-regs/regulations/standardnumber/1918/1918.95",
      "source_document_date": "",
      "verification_date": "2026-07-27",
      "verification_tier": "★",
      "source_text_note": "The standard uses a sufficiency requirement rather than an employee-count table."
    },
    {
      "record_id": "longshoring-07",
      "dataset_version": "1.0.0",
      "jurisdiction_level": "Federal",
      "jurisdiction_name": "United States",
      "workplace_category": "Longshoring",
      "standard_number": "29 CFR 1918.95",
      "requirement_type": "privacy_lock",
      "requirement_text": "Separate compartments must have latch-equipped doors.",
      "employee_scope_text": "Employees performing covered longshoring work.",
      "minimum_facility_text": "No employee-count table. Fixed or portable toilets must be sufficient for employees’ sanitary requirements.",
      "portable_facility_status": "Fixed or portable toilets are expressly allowed.",
      "access_rule": "Toilet and washing facilities must be readily accessible at the worksite.",
      "service_rule": "Toilets must be regularly cleaned and maintained in good order.",
      "washing_rule": "Running water—hot and cold or tepid—must be available at a minimum of one accessible location. Potable water may substitute where permanent facilities are not available. Soap and drying means are required.",
      "privacy_lock_rule": "Separate compartments must have latch-equipped doors.",
      "sex_separation_rule": "Separate facilities are required for each sex unless the toilet room will be occupied by only one person at a time.",
      "exception_text": "The standard provides a potable-water substitution where permanent washing facilities are not available.",
      "source_agency": "U.S. Occupational Safety and Health Administration",
      "source_title": "29 CFR 1918.95 — Sanitation",
      "source_url": "https://www.osha.gov/laws-regs/regulations/standardnumber/1918/1918.95",
      "source_document_date": "",
      "verification_date": "2026-07-27",
      "verification_tier": "★",
      "source_text_note": "The standard uses a sufficiency requirement rather than an employee-count table."
    },
    {
      "record_id": "longshoring-08",
      "dataset_version": "1.0.0",
      "jurisdiction_level": "Federal",
      "jurisdiction_name": "United States",
      "workplace_category": "Longshoring",
      "standard_number": "29 CFR 1918.95",
      "requirement_type": "sex_separation",
      "requirement_text": "Separate facilities are required for each sex unless the toilet room will be occupied by only one person at a time.",
      "employee_scope_text": "Employees performing covered longshoring work.",
      "minimum_facility_text": "No employee-count table. Fixed or portable toilets must be sufficient for employees’ sanitary requirements.",
      "portable_facility_status": "Fixed or portable toilets are expressly allowed.",
      "access_rule": "Toilet and washing facilities must be readily accessible at the worksite.",
      "service_rule": "Toilets must be regularly cleaned and maintained in good order.",
      "washing_rule": "Running water—hot and cold or tepid—must be available at a minimum of one accessible location. Potable water may substitute where permanent facilities are not available. Soap and drying means are required.",
      "privacy_lock_rule": "Separate compartments must have latch-equipped doors.",
      "sex_separation_rule": "Separate facilities are required for each sex unless the toilet room will be occupied by only one person at a time.",
      "exception_text": "The standard provides a potable-water substitution where permanent washing facilities are not available.",
      "source_agency": "U.S. Occupational Safety and Health Administration",
      "source_title": "29 CFR 1918.95 — Sanitation",
      "source_url": "https://www.osha.gov/laws-regs/regulations/standardnumber/1918/1918.95",
      "source_document_date": "",
      "verification_date": "2026-07-27",
      "verification_tier": "★",
      "source_text_note": "The standard uses a sufficiency requirement rather than an employee-count table."
    },
    {
      "record_id": "longshoring-09",
      "dataset_version": "1.0.0",
      "jurisdiction_level": "Federal",
      "jurisdiction_name": "United States",
      "workplace_category": "Longshoring",
      "standard_number": "29 CFR 1918.95",
      "requirement_type": "exceptions",
      "requirement_text": "The standard provides a potable-water substitution where permanent washing facilities are not available.",
      "employee_scope_text": "Employees performing covered longshoring work.",
      "minimum_facility_text": "No employee-count table. Fixed or portable toilets must be sufficient for employees’ sanitary requirements.",
      "portable_facility_status": "Fixed or portable toilets are expressly allowed.",
      "access_rule": "Toilet and washing facilities must be readily accessible at the worksite.",
      "service_rule": "Toilets must be regularly cleaned and maintained in good order.",
      "washing_rule": "Running water—hot and cold or tepid—must be available at a minimum of one accessible location. Potable water may substitute where permanent facilities are not available. Soap and drying means are required.",
      "privacy_lock_rule": "Separate compartments must have latch-equipped doors.",
      "sex_separation_rule": "Separate facilities are required for each sex unless the toilet room will be occupied by only one person at a time.",
      "exception_text": "The standard provides a potable-water substitution where permanent washing facilities are not available.",
      "source_agency": "U.S. Occupational Safety and Health Administration",
      "source_title": "29 CFR 1918.95 — Sanitation",
      "source_url": "https://www.osha.gov/laws-regs/regulations/standardnumber/1918/1918.95",
      "source_document_date": "",
      "verification_date": "2026-07-27",
      "verification_tier": "★",
      "source_text_note": "The standard uses a sufficiency requirement rather than an employee-count table."
    }
  ],
  "state_jurisdiction": [
    {
      "jurisdiction": "Alabama",
      "private_sector_authority": "Federal OSHA",
      "public_employee_authority": "Not covered by federal OSHA; check applicable public-employer law, policy, or other authority",
      "plan_category": "No approved State Plan",
      "verification_date": "2026-07-27",
      "verification_tier": "★",
      "source_url": "https://www.osha.gov/stateplans"
    },
    {
      "jurisdiction": "Alaska",
      "private_sector_authority": "OSHA-approved State Plan",
      "public_employee_authority": "OSHA-approved State Plan",
      "plan_category": "Full State Plan",
      "verification_date": "2026-07-27",
      "verification_tier": "★",
      "source_url": "https://www.osha.gov/stateplans"
    },
    {
      "jurisdiction": "Arizona",
      "private_sector_authority": "OSHA-approved State Plan",
      "public_employee_authority": "OSHA-approved State Plan",
      "plan_category": "Full State Plan",
      "verification_date": "2026-07-27",
      "verification_tier": "★",
      "source_url": "https://www.osha.gov/stateplans"
    },
    {
      "jurisdiction": "Arkansas",
      "private_sector_authority": "Federal OSHA",
      "public_employee_authority": "Not covered by federal OSHA; check applicable public-employer law, policy, or other authority",
      "plan_category": "No approved State Plan",
      "verification_date": "2026-07-27",
      "verification_tier": "★",
      "source_url": "https://www.osha.gov/stateplans"
    },
    {
      "jurisdiction": "California",
      "private_sector_authority": "OSHA-approved State Plan",
      "public_employee_authority": "OSHA-approved State Plan",
      "plan_category": "Full State Plan",
      "verification_date": "2026-07-27",
      "verification_tier": "★",
      "source_url": "https://www.osha.gov/stateplans"
    },
    {
      "jurisdiction": "Colorado",
      "private_sector_authority": "Federal OSHA",
      "public_employee_authority": "Not covered by federal OSHA; check applicable public-employer law, policy, or other authority",
      "plan_category": "No approved State Plan",
      "verification_date": "2026-07-27",
      "verification_tier": "★",
      "source_url": "https://www.osha.gov/stateplans"
    },
    {
      "jurisdiction": "Connecticut",
      "private_sector_authority": "Federal OSHA",
      "public_employee_authority": "OSHA-approved State Plan",
      "plan_category": "Public-sector-only State Plan",
      "verification_date": "2026-07-27",
      "verification_tier": "★",
      "source_url": "https://www.osha.gov/stateplans"
    },
    {
      "jurisdiction": "Delaware",
      "private_sector_authority": "Federal OSHA",
      "public_employee_authority": "Not covered by federal OSHA; check applicable public-employer law, policy, or other authority",
      "plan_category": "No approved State Plan",
      "verification_date": "2026-07-27",
      "verification_tier": "★",
      "source_url": "https://www.osha.gov/stateplans"
    },
    {
      "jurisdiction": "Florida",
      "private_sector_authority": "Federal OSHA",
      "public_employee_authority": "Not covered by federal OSHA; check applicable public-employer law, policy, or other authority",
      "plan_category": "No approved State Plan",
      "verification_date": "2026-07-27",
      "verification_tier": "★",
      "source_url": "https://www.osha.gov/stateplans"
    },
    {
      "jurisdiction": "Georgia",
      "private_sector_authority": "Federal OSHA",
      "public_employee_authority": "Not covered by federal OSHA; check applicable public-employer law, policy, or other authority",
      "plan_category": "No approved State Plan",
      "verification_date": "2026-07-27",
      "verification_tier": "★",
      "source_url": "https://www.osha.gov/stateplans"
    },
    {
      "jurisdiction": "Hawaii",
      "private_sector_authority": "OSHA-approved State Plan",
      "public_employee_authority": "OSHA-approved State Plan",
      "plan_category": "Full State Plan",
      "verification_date": "2026-07-27",
      "verification_tier": "★",
      "source_url": "https://www.osha.gov/stateplans"
    },
    {
      "jurisdiction": "Idaho",
      "private_sector_authority": "Federal OSHA",
      "public_employee_authority": "Not covered by federal OSHA; check applicable public-employer law, policy, or other authority",
      "plan_category": "No approved State Plan",
      "verification_date": "2026-07-27",
      "verification_tier": "★",
      "source_url": "https://www.osha.gov/stateplans"
    },
    {
      "jurisdiction": "Illinois",
      "private_sector_authority": "Federal OSHA",
      "public_employee_authority": "OSHA-approved State Plan",
      "plan_category": "Public-sector-only State Plan",
      "verification_date": "2026-07-27",
      "verification_tier": "★",
      "source_url": "https://www.osha.gov/stateplans"
    },
    {
      "jurisdiction": "Indiana",
      "private_sector_authority": "OSHA-approved State Plan",
      "public_employee_authority": "OSHA-approved State Plan",
      "plan_category": "Full State Plan",
      "verification_date": "2026-07-27",
      "verification_tier": "★",
      "source_url": "https://www.osha.gov/stateplans"
    },
    {
      "jurisdiction": "Iowa",
      "private_sector_authority": "OSHA-approved State Plan",
      "public_employee_authority": "OSHA-approved State Plan",
      "plan_category": "Full State Plan",
      "verification_date": "2026-07-27",
      "verification_tier": "★",
      "source_url": "https://www.osha.gov/stateplans"
    },
    {
      "jurisdiction": "Kansas",
      "private_sector_authority": "Federal OSHA",
      "public_employee_authority": "Not covered by federal OSHA; check applicable public-employer law, policy, or other authority",
      "plan_category": "No approved State Plan",
      "verification_date": "2026-07-27",
      "verification_tier": "★",
      "source_url": "https://www.osha.gov/stateplans"
    },
    {
      "jurisdiction": "Kentucky",
      "private_sector_authority": "OSHA-approved State Plan",
      "public_employee_authority": "OSHA-approved State Plan",
      "plan_category": "Full State Plan",
      "verification_date": "2026-07-27",
      "verification_tier": "★",
      "source_url": "https://www.osha.gov/stateplans"
    },
    {
      "jurisdiction": "Louisiana",
      "private_sector_authority": "Federal OSHA",
      "public_employee_authority": "Not covered by federal OSHA; check applicable public-employer law, policy, or other authority",
      "plan_category": "No approved State Plan",
      "verification_date": "2026-07-27",
      "verification_tier": "★",
      "source_url": "https://www.osha.gov/stateplans"
    },
    {
      "jurisdiction": "Maine",
      "private_sector_authority": "Federal OSHA",
      "public_employee_authority": "OSHA-approved State Plan",
      "plan_category": "Public-sector-only State Plan",
      "verification_date": "2026-07-27",
      "verification_tier": "★",
      "source_url": "https://www.osha.gov/stateplans"
    },
    {
      "jurisdiction": "Maryland",
      "private_sector_authority": "OSHA-approved State Plan",
      "public_employee_authority": "OSHA-approved State Plan",
      "plan_category": "Full State Plan",
      "verification_date": "2026-07-27",
      "verification_tier": "★",
      "source_url": "https://www.osha.gov/stateplans"
    },
    {
      "jurisdiction": "Massachusetts",
      "private_sector_authority": "Federal OSHA",
      "public_employee_authority": "OSHA-approved State Plan",
      "plan_category": "Public-sector-only State Plan",
      "verification_date": "2026-07-27",
      "verification_tier": "★",
      "source_url": "https://www.osha.gov/stateplans"
    },
    {
      "jurisdiction": "Michigan",
      "private_sector_authority": "OSHA-approved State Plan",
      "public_employee_authority": "OSHA-approved State Plan",
      "plan_category": "Full State Plan",
      "verification_date": "2026-07-27",
      "verification_tier": "★",
      "source_url": "https://www.osha.gov/stateplans"
    },
    {
      "jurisdiction": "Minnesota",
      "private_sector_authority": "OSHA-approved State Plan",
      "public_employee_authority": "OSHA-approved State Plan",
      "plan_category": "Full State Plan",
      "verification_date": "2026-07-27",
      "verification_tier": "★",
      "source_url": "https://www.osha.gov/stateplans"
    },
    {
      "jurisdiction": "Mississippi",
      "private_sector_authority": "Federal OSHA",
      "public_employee_authority": "Not covered by federal OSHA; check applicable public-employer law, policy, or other authority",
      "plan_category": "No approved State Plan",
      "verification_date": "2026-07-27",
      "verification_tier": "★",
      "source_url": "https://www.osha.gov/stateplans"
    },
    {
      "jurisdiction": "Missouri",
      "private_sector_authority": "Federal OSHA",
      "public_employee_authority": "Not covered by federal OSHA; check applicable public-employer law, policy, or other authority",
      "plan_category": "No approved State Plan",
      "verification_date": "2026-07-27",
      "verification_tier": "★",
      "source_url": "https://www.osha.gov/stateplans"
    },
    {
      "jurisdiction": "Montana",
      "private_sector_authority": "Federal OSHA",
      "public_employee_authority": "Not covered by federal OSHA; check applicable public-employer law, policy, or other authority",
      "plan_category": "No approved State Plan",
      "verification_date": "2026-07-27",
      "verification_tier": "★",
      "source_url": "https://www.osha.gov/stateplans"
    },
    {
      "jurisdiction": "Nebraska",
      "private_sector_authority": "Federal OSHA",
      "public_employee_authority": "Not covered by federal OSHA; check applicable public-employer law, policy, or other authority",
      "plan_category": "No approved State Plan",
      "verification_date": "2026-07-27",
      "verification_tier": "★",
      "source_url": "https://www.osha.gov/stateplans"
    },
    {
      "jurisdiction": "Nevada",
      "private_sector_authority": "OSHA-approved State Plan",
      "public_employee_authority": "OSHA-approved State Plan",
      "plan_category": "Full State Plan",
      "verification_date": "2026-07-27",
      "verification_tier": "★",
      "source_url": "https://www.osha.gov/stateplans"
    },
    {
      "jurisdiction": "New Hampshire",
      "private_sector_authority": "Federal OSHA",
      "public_employee_authority": "Not covered by federal OSHA; check applicable public-employer law, policy, or other authority",
      "plan_category": "No approved State Plan",
      "verification_date": "2026-07-27",
      "verification_tier": "★",
      "source_url": "https://www.osha.gov/stateplans"
    },
    {
      "jurisdiction": "New Jersey",
      "private_sector_authority": "Federal OSHA",
      "public_employee_authority": "OSHA-approved State Plan",
      "plan_category": "Public-sector-only State Plan",
      "verification_date": "2026-07-27",
      "verification_tier": "★",
      "source_url": "https://www.osha.gov/stateplans"
    },
    {
      "jurisdiction": "New Mexico",
      "private_sector_authority": "OSHA-approved State Plan",
      "public_employee_authority": "OSHA-approved State Plan",
      "plan_category": "Full State Plan",
      "verification_date": "2026-07-27",
      "verification_tier": "★",
      "source_url": "https://www.osha.gov/stateplans"
    },
    {
      "jurisdiction": "New York",
      "private_sector_authority": "Federal OSHA",
      "public_employee_authority": "OSHA-approved State Plan",
      "plan_category": "Public-sector-only State Plan",
      "verification_date": "2026-07-27",
      "verification_tier": "★",
      "source_url": "https://www.osha.gov/stateplans"
    },
    {
      "jurisdiction": "North Carolina",
      "private_sector_authority": "OSHA-approved State Plan",
      "public_employee_authority": "OSHA-approved State Plan",
      "plan_category": "Full State Plan",
      "verification_date": "2026-07-27",
      "verification_tier": "★",
      "source_url": "https://www.osha.gov/stateplans"
    },
    {
      "jurisdiction": "North Dakota",
      "private_sector_authority": "Federal OSHA",
      "public_employee_authority": "Not covered by federal OSHA; check applicable public-employer law, policy, or other authority",
      "plan_category": "No approved State Plan",
      "verification_date": "2026-07-27",
      "verification_tier": "★",
      "source_url": "https://www.osha.gov/stateplans"
    },
    {
      "jurisdiction": "Ohio",
      "private_sector_authority": "Federal OSHA",
      "public_employee_authority": "Not covered by federal OSHA; check applicable public-employer law, policy, or other authority",
      "plan_category": "No approved State Plan",
      "verification_date": "2026-07-27",
      "verification_tier": "★",
      "source_url": "https://www.osha.gov/stateplans"
    },
    {
      "jurisdiction": "Oklahoma",
      "private_sector_authority": "Federal OSHA",
      "public_employee_authority": "Not covered by federal OSHA; check applicable public-employer law, policy, or other authority",
      "plan_category": "No approved State Plan",
      "verification_date": "2026-07-27",
      "verification_tier": "★",
      "source_url": "https://www.osha.gov/stateplans"
    },
    {
      "jurisdiction": "Oregon",
      "private_sector_authority": "OSHA-approved State Plan",
      "public_employee_authority": "OSHA-approved State Plan",
      "plan_category": "Full State Plan",
      "verification_date": "2026-07-27",
      "verification_tier": "★",
      "source_url": "https://www.osha.gov/stateplans"
    },
    {
      "jurisdiction": "Pennsylvania",
      "private_sector_authority": "Federal OSHA",
      "public_employee_authority": "Not covered by federal OSHA; check applicable public-employer law, policy, or other authority",
      "plan_category": "No approved State Plan",
      "verification_date": "2026-07-27",
      "verification_tier": "★",
      "source_url": "https://www.osha.gov/stateplans"
    },
    {
      "jurisdiction": "Rhode Island",
      "private_sector_authority": "Federal OSHA",
      "public_employee_authority": "Not covered by federal OSHA; check applicable public-employer law, policy, or other authority",
      "plan_category": "No approved State Plan",
      "verification_date": "2026-07-27",
      "verification_tier": "★",
      "source_url": "https://www.osha.gov/stateplans"
    },
    {
      "jurisdiction": "South Carolina",
      "private_sector_authority": "OSHA-approved State Plan",
      "public_employee_authority": "OSHA-approved State Plan",
      "plan_category": "Full State Plan",
      "verification_date": "2026-07-27",
      "verification_tier": "★",
      "source_url": "https://www.osha.gov/stateplans"
    },
    {
      "jurisdiction": "South Dakota",
      "private_sector_authority": "Federal OSHA",
      "public_employee_authority": "Not covered by federal OSHA; check applicable public-employer law, policy, or other authority",
      "plan_category": "No approved State Plan",
      "verification_date": "2026-07-27",
      "verification_tier": "★",
      "source_url": "https://www.osha.gov/stateplans"
    },
    {
      "jurisdiction": "Tennessee",
      "private_sector_authority": "OSHA-approved State Plan",
      "public_employee_authority": "OSHA-approved State Plan",
      "plan_category": "Full State Plan",
      "verification_date": "2026-07-27",
      "verification_tier": "★",
      "source_url": "https://www.osha.gov/stateplans"
    },
    {
      "jurisdiction": "Texas",
      "private_sector_authority": "Federal OSHA",
      "public_employee_authority": "Not covered by federal OSHA; check applicable public-employer law, policy, or other authority",
      "plan_category": "No approved State Plan",
      "verification_date": "2026-07-27",
      "verification_tier": "★",
      "source_url": "https://www.osha.gov/stateplans"
    },
    {
      "jurisdiction": "Utah",
      "private_sector_authority": "OSHA-approved State Plan",
      "public_employee_authority": "OSHA-approved State Plan",
      "plan_category": "Full State Plan",
      "verification_date": "2026-07-27",
      "verification_tier": "★",
      "source_url": "https://www.osha.gov/stateplans"
    },
    {
      "jurisdiction": "Vermont",
      "private_sector_authority": "OSHA-approved State Plan",
      "public_employee_authority": "OSHA-approved State Plan",
      "plan_category": "Full State Plan",
      "verification_date": "2026-07-27",
      "verification_tier": "★",
      "source_url": "https://www.osha.gov/stateplans"
    },
    {
      "jurisdiction": "Virginia",
      "private_sector_authority": "OSHA-approved State Plan",
      "public_employee_authority": "OSHA-approved State Plan",
      "plan_category": "Full State Plan",
      "verification_date": "2026-07-27",
      "verification_tier": "★",
      "source_url": "https://www.osha.gov/stateplans"
    },
    {
      "jurisdiction": "Washington",
      "private_sector_authority": "OSHA-approved State Plan",
      "public_employee_authority": "OSHA-approved State Plan",
      "plan_category": "Full State Plan",
      "verification_date": "2026-07-27",
      "verification_tier": "★",
      "source_url": "https://www.osha.gov/stateplans"
    },
    {
      "jurisdiction": "West Virginia",
      "private_sector_authority": "Federal OSHA",
      "public_employee_authority": "Not covered by federal OSHA; check applicable public-employer law, policy, or other authority",
      "plan_category": "No approved State Plan",
      "verification_date": "2026-07-27",
      "verification_tier": "★",
      "source_url": "https://www.osha.gov/stateplans"
    },
    {
      "jurisdiction": "Wisconsin",
      "private_sector_authority": "Federal OSHA",
      "public_employee_authority": "Not covered by federal OSHA; check applicable public-employer law, policy, or other authority",
      "plan_category": "No approved State Plan",
      "verification_date": "2026-07-27",
      "verification_tier": "★",
      "source_url": "https://www.osha.gov/stateplans"
    },
    {
      "jurisdiction": "Wyoming",
      "private_sector_authority": "OSHA-approved State Plan",
      "public_employee_authority": "OSHA-approved State Plan",
      "plan_category": "Full State Plan",
      "verification_date": "2026-07-27",
      "verification_tier": "★",
      "source_url": "https://www.osha.gov/stateplans"
    },
    {
      "jurisdiction": "District of Columbia",
      "private_sector_authority": "Federal OSHA",
      "public_employee_authority": "Not covered by federal OSHA; check applicable public-employer law, policy, or other authority",
      "plan_category": "No approved State Plan",
      "verification_date": "2026-07-27",
      "verification_tier": "★",
      "source_url": "https://www.osha.gov/stateplans"
    },
    {
      "jurisdiction": "Puerto Rico",
      "private_sector_authority": "OSHA-approved State Plan",
      "public_employee_authority": "OSHA-approved State Plan",
      "plan_category": "Full State Plan",
      "verification_date": "2026-07-27",
      "verification_tier": "★",
      "source_url": "https://www.osha.gov/stateplans"
    },
    {
      "jurisdiction": "U.S. Virgin Islands",
      "private_sector_authority": "Federal OSHA",
      "public_employee_authority": "OSHA-approved State Plan",
      "plan_category": "Public-sector-only State Plan",
      "verification_date": "2026-07-27",
      "verification_tier": "★",
      "source_url": "https://www.osha.gov/stateplans"
    }
  ],
  "threshold_audit": [
    {
      "standard_number": "29 CFR 1926.51",
      "table_name": "Table D-1",
      "printed_bands": "20 or less | 20 or more | 200 or more",
      "overlap_finding": "Overlaps at exactly 20 and exactly 200; the middle row has no printed upper boundary.",
      "unassigned_values": "",
      "denominator_basis": "Total employees/workers",
      "fraction_language_present": "No",
      "verification_date": "2026-07-27",
      "verification_tier": "★",
      "source_url": "https://www.osha.gov/laws-regs/regulations/standardnumber/1926/1926.51"
    },
    {
      "standard_number": "29 CFR 1910.120(n)",
      "table_name": "Table H-120.2",
      "printed_bands": "20 or fewer | more than 20, fewer than 200 | more than 200",
      "overlap_finding": "None",
      "unassigned_values": "Exactly 200 employees",
      "denominator_basis": "Employees/workers at temporary hazardous-waste worksites",
      "fraction_language_present": "No",
      "verification_date": "2026-07-27",
      "verification_tier": "★",
      "source_url": "https://www.osha.gov/laws-regs/regulations/standardnumber/1910/1910.120"
    },
    {
      "standard_number": "29 CFR 1926.65(n)",
      "table_name": "Table D-65.2",
      "printed_bands": "20 or fewer | more than 20, fewer than 200 | more than 200",
      "overlap_finding": "None",
      "unassigned_values": "Exactly 200 employees",
      "denominator_basis": "Employees/workers at temporary hazardous-waste worksites",
      "fraction_language_present": "No",
      "verification_date": "2026-07-27",
      "verification_tier": "★",
      "source_url": "https://www.osha.gov/laws-regs/regulations/standardnumber/1926/1926.65"
    },
    {
      "standard_number": "29 CFR 1910.141",
      "table_name": "Table J-1",
      "printed_bands": "1–15 | 16–35 | 36–55 | 56–80 | 81–110 | 111–150 | over 150",
      "overlap_finding": "None",
      "unassigned_values": "None",
      "denominator_basis": "Per sex; maximum number present at one time on a regular shift",
      "fraction_language_present": "No",
      "verification_date": "2026-07-27",
      "verification_tier": "★",
      "source_url": "https://www.osha.gov/laws-regs/regulations/standardnumber/1910/1910.141"
    },
    {
      "standard_number": "29 CFR 1915.88",
      "table_name": "Table F-2",
      "printed_bands": "1–15 | 16–35 | 36–55 | 56–80 | 81–110 | 111–150 | over 150",
      "overlap_finding": "None",
      "unassigned_values": "None",
      "denominator_basis": "Per sex; maximum number present at one time during a workshift",
      "fraction_language_present": "No",
      "verification_date": "2026-07-27",
      "verification_tier": "★",
      "source_url": "https://www.osha.gov/laws-regs/regulations/standardnumber/1915/1915.88"
    },
    {
      "standard_number": "29 CFR 1928.110",
      "table_name": "Field-sanitation ratio",
      "printed_bands": "1 toilet and 1 handwashing facility per 20 employees or fraction thereof",
      "overlap_finding": "None",
      "unassigned_values": "None",
      "denominator_basis": "Employees engaged in hand-labor field operations",
      "fraction_language_present": "Yes",
      "verification_date": "2026-07-27",
      "verification_tier": "★",
      "source_url": "https://www.osha.gov/laws-regs/regulations/standardnumber/1928/1928.110"
    }
  ],
  "claim_audit": [
    {
      "claim_text": "OSHA requires one porta potty per 20 construction workers.",
      "classification": "Incomplete",
      "finding": "That is only the first row of federal construction Table D-1. Above 20, the printed rule uses a toilet-seat-and-urinal ratio.",
      "controlling_source": "29 CFR 1926.51(c)(1)",
      "source_url": "https://www.osha.gov/laws-regs/regulations/standardnumber/1926/1926.51",
      "verification_date": "2026-07-27",
      "verification_tier": "★"
    },
    {
      "claim_text": "Federal OSHA requires construction toilets within 200 feet.",
      "classification": "Misattributed",
      "finding": "No universal 200-foot limit appears in the federal construction standard or the OSHA interpretations reviewed. Washington uses a 200-foot rule.",
      "controlling_source": "WAC 296-155-140(5)(c)(ii)",
      "source_url": "https://app.leg.wa.gov/wac/default.aspx?cite=296-155-140",
      "verification_date": "2026-07-27",
      "verification_tier": "★"
    },
    {
      "claim_text": "OSHA’s construction distance rule is one-quarter mile.",
      "classification": "Wrong standard",
      "finding": "The one-quarter-mile rule applies to agricultural hand-labor field sanitation, not ordinary construction.",
      "controlling_source": "29 CFR 1928.110(c)(2)",
      "source_url": "https://www.osha.gov/laws-regs/regulations/standardnumber/1928/1928.110",
      "verification_date": "2026-07-27",
      "verification_tier": "★"
    },
    {
      "claim_text": "OSHA uses less than 10 minutes for construction toilet access.",
      "classification": "Supported with scope qualifier",
      "finding": "OSHA states that less than 10 minutes is the general starting point for prompt access in its 2002 mobile-crew letter and applies the same starting point to fixed construction sites in its February 23, 2005 letter. The figure is interpretation guidance, not text in the regulation.",
      "controlling_source": "OSHA letters dated June 7, 2002 and February 23, 2005",
      "source_url": "https://www.osha.gov/laws-regs/standardinterpretations/2005-02-23",
      "verification_date": "2026-07-27",
      "verification_tier": "★"
    },
    {
      "claim_text": "OSHA requires weekly servicing.",
      "classification": "Too broad",
      "finding": "Federal construction OSHA requires sanitary condition and cites an ANSI servicing schedule as one way to meet that obligation. Weekly service is the cited example for a toilet used by up to 10 people.",
      "controlling_source": "OSHA interpretation dated May 17, 2006",
      "source_url": "https://www.osha.gov/laws-regs/standardinterpretations/2006-05-17-0",
      "verification_date": "2026-07-27",
      "verification_tier": "★"
    },
    {
      "claim_text": "Every federal construction site needs a handwashing station.",
      "classification": "Not supported as a universal federal rule",
      "finding": "Section 1926.51(f)(1) is triggered by specified harmful-contaminant operations; OSHA states that §1926.51(f)(3) applies only to permanent places of employment.",
      "controlling_source": "29 CFR 1926.51(f); OSHA interpretation dated July 20, 2005",
      "source_url": "https://www.osha.gov/laws-regs/standardinterpretations/2005-07-20",
      "verification_date": "2026-07-27",
      "verification_tier": "★"
    },
    {
      "claim_text": "Hand sanitizer is always enough when water is unavailable.",
      "classification": "Not supported",
      "finding": "Where §1926.51(f)(1) applies, OSHA states that waterless cleaner and towels or rags typically are not sufficient to remove harmful contaminants.",
      "controlling_source": "OSHA interpretation dated July 20, 2005",
      "source_url": "https://www.osha.gov/laws-regs/standardinterpretations/2005-07-20",
      "verification_date": "2026-07-27",
      "verification_tier": "★"
    },
    {
      "claim_text": "Every construction porta potty must lock from the inside.",
      "classification": "Too broad",
      "finding": "Inside locks or latches are express in HAZWOPER, agriculture, maritime, shipyard single-occupancy exceptions, and Washington, but not in ordinary federal construction §1926.51(c).",
      "controlling_source": "29 CFR 1926.51(c) and worksite-specific standards",
      "source_url": "https://www.osha.gov/laws-regs/regulations/standardnumber/1926/1926.51",
      "verification_date": "2026-07-27",
      "verification_tier": "★"
    },
    {
      "claim_text": "Federal OSHA requires separate men’s and women’s toilets in ordinary construction.",
      "classification": "Too broad",
      "finding": "Sex separation is express in general industry, shipyards, marine-terminal and longshoring rules, and verified State Plan rules, but not in ordinary federal construction §1926.51(c).",
      "controlling_source": "29 CFR 1926.51(c) and comparison standards",
      "source_url": "https://www.osha.gov/laws-regs/regulations/standardnumber/1926/1926.51",
      "verification_date": "2026-07-27",
      "verification_tier": "★"
    },
    {
      "claim_text": "Five percent of employee-only construction porta potties must be ADA accessible.",
      "classification": "Contradicted as a blanket claim",
      "finding": "Portable units used exclusively by construction personnel are exempt from §213 and accessible-route requirements under 2010 ADA Standards §203.2. Separate employment-accommodation duties may still apply.",
      "controlling_source": "2010 ADA Standards §203.2",
      "source_url": "https://www.access-board.gov/ada/chapter/ch02/",
      "verification_date": "2026-07-27",
      "verification_tier": "★"
    },
    {
      "claim_text": "A toilet physically present on site always counts toward the minimum.",
      "classification": "False if inaccessible or unsanitary",
      "finding": "OSHA states that toilets taking too long to reach or in unsanitary condition are not genuinely provided.",
      "controlling_source": "OSHA interpretations dated February 23, 2005 and May 17, 2006",
      "source_url": "https://www.osha.gov/laws-regs/standardinterpretations/2006-05-17-0",
      "verification_date": "2026-07-27",
      "verification_tier": "★"
    },
    {
      "claim_text": "All OSHA workplaces use the same portable-toilet ratio.",
      "classification": "False",
      "finding": "The eight standards compared use different tables, denominators, conditions, and in two cases no employee-count table.",
      "controlling_source": "Federal crosswalk in dataset version 1.0.0",
      "source_url": "https://www.osha.gov/restrooms-sanitation",
      "verification_date": "2026-07-27",
      "verification_tier": "★"
    },
    {
      "claim_text": "Portable toilets always satisfy general-industry toilet rules.",
      "classification": "False",
      "finding": "OSHA’s May 18, 1999 interpretation treats substitution as potentially de minimis only under specified conditions.",
      "controlling_source": "OSHA interpretation dated May 18, 1999",
      "source_url": "https://www.osha.gov/laws-regs/standardinterpretations/1999-05-18",
      "verification_date": "2026-07-27",
      "verification_tier": "★"
    }
  ],
  "data_dictionary": [
    {
      "distribution": "osha-sanitation-crosswalk-v1.0.0.csv",
      "field_name": "record_id",
      "definition": "Permanent unique record identifier.",
      "verification_date": "2026-07-27"
    },
    {
      "distribution": "osha-sanitation-crosswalk-v1.0.0.csv",
      "field_name": "dataset_version",
      "definition": "Semantic version of the dataset.",
      "verification_date": "2026-07-27"
    },
    {
      "distribution": "osha-sanitation-crosswalk-v1.0.0.csv",
      "field_name": "jurisdiction_level",
      "definition": "Federal, state, territory, or local level.",
      "verification_date": "2026-07-27"
    },
    {
      "distribution": "osha-sanitation-crosswalk-v1.0.0.csv",
      "field_name": "jurisdiction_name",
      "definition": "Name of the governing jurisdiction.",
      "verification_date": "2026-07-27"
    },
    {
      "distribution": "osha-sanitation-crosswalk-v1.0.0.csv",
      "field_name": "workplace_category",
      "definition": "Worksite category to which the record applies.",
      "verification_date": "2026-07-27"
    },
    {
      "distribution": "osha-sanitation-crosswalk-v1.0.0.csv",
      "field_name": "standard_number",
      "definition": "Controlling regulatory citation.",
      "verification_date": "2026-07-27"
    },
    {
      "distribution": "osha-sanitation-crosswalk-v1.0.0.csv",
      "field_name": "requirement_type",
      "definition": "Normalized requirement category.",
      "verification_date": "2026-07-27"
    },
    {
      "distribution": "osha-sanitation-crosswalk-v1.0.0.csv",
      "field_name": "requirement_text",
      "definition": "Normalized statement for the requirement category.",
      "verification_date": "2026-07-27"
    },
    {
      "distribution": "osha-sanitation-crosswalk-v1.0.0.csv",
      "field_name": "employee_scope_text",
      "definition": "Source-preserved or source-faithful employee denominator and scope.",
      "verification_date": "2026-07-27"
    },
    {
      "distribution": "osha-sanitation-crosswalk-v1.0.0.csv",
      "field_name": "minimum_facility_text",
      "definition": "Source-preserved or source-faithful minimum facility wording.",
      "verification_date": "2026-07-27"
    },
    {
      "distribution": "osha-sanitation-crosswalk-v1.0.0.csv",
      "field_name": "portable_facility_status",
      "definition": "Whether and when portable facilities are permitted.",
      "verification_date": "2026-07-27"
    },
    {
      "distribution": "osha-sanitation-crosswalk-v1.0.0.csv",
      "field_name": "access_rule",
      "definition": "Access, distance, time, or availability rule.",
      "verification_date": "2026-07-27"
    },
    {
      "distribution": "osha-sanitation-crosswalk-v1.0.0.csv",
      "field_name": "service_rule",
      "definition": "Sanitary-condition, servicing, cleaning, or inspection rule.",
      "verification_date": "2026-07-27"
    },
    {
      "distribution": "osha-sanitation-crosswalk-v1.0.0.csv",
      "field_name": "washing_rule",
      "definition": "Handwashing or lavatory rule.",
      "verification_date": "2026-07-27"
    },
    {
      "distribution": "osha-sanitation-crosswalk-v1.0.0.csv",
      "field_name": "privacy_lock_rule",
      "definition": "Privacy, latch, or inside-lock rule.",
      "verification_date": "2026-07-27"
    },
    {
      "distribution": "osha-sanitation-crosswalk-v1.0.0.csv",
      "field_name": "sex_separation_rule",
      "definition": "Sex-separation or single-occupancy exception.",
      "verification_date": "2026-07-27"
    },
    {
      "distribution": "osha-sanitation-crosswalk-v1.0.0.csv",
      "field_name": "exception_text",
      "definition": "Mobile-crew, unattended-site, short-duration, or other exception.",
      "verification_date": "2026-07-27"
    },
    {
      "distribution": "osha-sanitation-crosswalk-v1.0.0.csv",
      "field_name": "source_agency",
      "definition": "Issuing agency.",
      "verification_date": "2026-07-27"
    },
    {
      "distribution": "osha-sanitation-crosswalk-v1.0.0.csv",
      "field_name": "source_title",
      "definition": "Title of the primary source.",
      "verification_date": "2026-07-27"
    },
    {
      "distribution": "osha-sanitation-crosswalk-v1.0.0.csv",
      "field_name": "source_url",
      "definition": "Direct primary-source URL.",
      "verification_date": "2026-07-27"
    },
    {
      "distribution": "osha-sanitation-crosswalk-v1.0.0.csv",
      "field_name": "source_document_date",
      "definition": "Date of the underlying document where a discrete date exists.",
      "verification_date": "2026-07-27"
    },
    {
      "distribution": "osha-sanitation-crosswalk-v1.0.0.csv",
      "field_name": "verification_date",
      "definition": "Date the source was re-opened and verified.",
      "verification_date": "2026-07-27"
    },
    {
      "distribution": "osha-sanitation-crosswalk-v1.0.0.csv",
      "field_name": "verification_tier",
      "definition": "★ directly verified; ● compiled but awaiting a second direct pass.",
      "verification_date": "2026-07-27"
    },
    {
      "distribution": "osha-sanitation-crosswalk-v1.0.0.csv",
      "field_name": "source_text_note",
      "definition": "Boundary, scope, or ambiguity note.",
      "verification_date": "2026-07-27"
    },
    {
      "distribution": "osha-state-jurisdiction-2026-07-27.csv",
      "field_name": "jurisdiction",
      "definition": "State, district, or territory name.",
      "verification_date": "2026-07-27"
    },
    {
      "distribution": "osha-state-jurisdiction-2026-07-27.csv",
      "field_name": "private_sector_authority",
      "definition": "Authority covering most private-sector workers.",
      "verification_date": "2026-07-27"
    },
    {
      "distribution": "osha-state-jurisdiction-2026-07-27.csv",
      "field_name": "public_employee_authority",
      "definition": "Authority covering state and local government workers.",
      "verification_date": "2026-07-27"
    },
    {
      "distribution": "osha-state-jurisdiction-2026-07-27.csv",
      "field_name": "plan_category",
      "definition": "Full State Plan, public-sector-only State Plan, or no approved State Plan.",
      "verification_date": "2026-07-27"
    },
    {
      "distribution": "osha-state-jurisdiction-2026-07-27.csv",
      "field_name": "verification_date",
      "definition": "Date the source was re-opened and verified.",
      "verification_date": "2026-07-27"
    },
    {
      "distribution": "osha-state-jurisdiction-2026-07-27.csv",
      "field_name": "verification_tier",
      "definition": "★ directly verified; ● compiled but awaiting a second direct pass.",
      "verification_date": "2026-07-27"
    },
    {
      "distribution": "osha-state-jurisdiction-2026-07-27.csv",
      "field_name": "source_url",
      "definition": "Direct primary-source URL.",
      "verification_date": "2026-07-27"
    },
    {
      "distribution": "osha-threshold-audit-v1.0.0.csv",
      "field_name": "standard_number",
      "definition": "Controlling regulatory citation.",
      "verification_date": "2026-07-27"
    },
    {
      "distribution": "osha-threshold-audit-v1.0.0.csv",
      "field_name": "table_name",
      "definition": "Official table or ratio name.",
      "verification_date": "2026-07-27"
    },
    {
      "distribution": "osha-threshold-audit-v1.0.0.csv",
      "field_name": "printed_bands",
      "definition": "Employee-count bands as printed.",
      "verification_date": "2026-07-27"
    },
    {
      "distribution": "osha-threshold-audit-v1.0.0.csv",
      "field_name": "overlap_finding",
      "definition": "Any overlapping boundary in the printed bands.",
      "verification_date": "2026-07-27"
    },
    {
      "distribution": "osha-threshold-audit-v1.0.0.csv",
      "field_name": "unassigned_values",
      "definition": "Employee counts omitted by the printed bands.",
      "verification_date": "2026-07-27"
    },
    {
      "distribution": "osha-threshold-audit-v1.0.0.csv",
      "field_name": "denominator_basis",
      "definition": "Employee denominator used by the table.",
      "verification_date": "2026-07-27"
    },
    {
      "distribution": "osha-threshold-audit-v1.0.0.csv",
      "field_name": "fraction_language_present",
      "definition": "Whether the source expressly includes fractions.",
      "verification_date": "2026-07-27"
    },
    {
      "distribution": "osha-threshold-audit-v1.0.0.csv",
      "field_name": "verification_date",
      "definition": "Date the source was re-opened and verified.",
      "verification_date": "2026-07-27"
    },
    {
      "distribution": "osha-threshold-audit-v1.0.0.csv",
      "field_name": "verification_tier",
      "definition": "★ directly verified; ● compiled but awaiting a second direct pass.",
      "verification_date": "2026-07-27"
    },
    {
      "distribution": "osha-threshold-audit-v1.0.0.csv",
      "field_name": "source_url",
      "definition": "Direct primary-source URL.",
      "verification_date": "2026-07-27"
    },
    {
      "distribution": "osha-claim-audit-v1.0.0.csv",
      "field_name": "claim_text",
      "definition": "Common statement tested against primary sources.",
      "verification_date": "2026-07-27"
    },
    {
      "distribution": "osha-claim-audit-v1.0.0.csv",
      "field_name": "classification",
      "definition": "Supported, incomplete, too broad, contradicted, misattributed, or other audit result.",
      "verification_date": "2026-07-27"
    },
    {
      "distribution": "osha-claim-audit-v1.0.0.csv",
      "field_name": "finding",
      "definition": "Source-based explanation of the classification.",
      "verification_date": "2026-07-27"
    },
    {
      "distribution": "osha-claim-audit-v1.0.0.csv",
      "field_name": "controlling_source",
      "definition": "Primary source controlling the audit result.",
      "verification_date": "2026-07-27"
    },
    {
      "distribution": "osha-claim-audit-v1.0.0.csv",
      "field_name": "source_url",
      "definition": "Direct primary-source URL.",
      "verification_date": "2026-07-27"
    },
    {
      "distribution": "osha-claim-audit-v1.0.0.csv",
      "field_name": "verification_date",
      "definition": "Date the source was re-opened and verified.",
      "verification_date": "2026-07-27"
    },
    {
      "distribution": "osha-claim-audit-v1.0.0.csv",
      "field_name": "verification_tier",
      "definition": "★ directly verified; ● compiled but awaiting a second direct pass.",
      "verification_date": "2026-07-27"
    }
  ]
}